Early real world experience with the CREDO heal stent for elective treatment of intracranial atherosclerotic disease

BACKGROUND: Intracranial atherosclerotic disease (ICAD) is a major cause of ischemic stroke and transient ischemic attack, particularly in Asian populations. Despite best medical therapy, symptomatic ICAD carries a substantial risk of recurrent ischemia. OBJECTIVE: To evaluate the safety and feasibility of the fibrin-heparin coated CREDO heal stent for the treatment of symptomatic high grade ICAD in routine clinical practice. METHODS: This retrospective observational case series included patients with symptomatic intracranial stenosis ≥70% treated with the CREDO heal stent. All patients were receiving best medical therapy and had at least one qualifying ischemic event. The primary safety endpoint was stroke, intracranial hemorrhage, or death within 30 days. Secondary endpoints included technical success, angiographic patency, recurrent ischemic events, and functional outcomes measured by the modified Rankin Scale (mRS). Clinical follow-up occurred at discharge, and at 30, 90, and 180 days, with CT angiography at 90 days and DSA at 180 days. RESULTS: Forty-five patients (78% men; mean age 64.8 years) were treated. Technical success was achieved in all cases, with stenosis reduced from 84.5% to ≤30%. No stroke, intracranial hemorrhage, or death occurred within 30 days. Clinical follow-up was complete in all patients at discharge, and at 90 days and 180 days. Imaging follow-up was available in 41 patients at 90 days and in all patients at 180 days, with no angiographic restenosis or stent thrombosis observed. Favorable functional outcome (mRS score ≤2) was observed in all patients at 6 months. CONCLUSION: In this retrospective series, elective percutaneous transluminal angioplasty and stenting using the CREDO heal stent appeared feasible and showed no major complications in this selected cohort.

Authors

Institutions

Publication Details

Journal
Journal of NeuroInterventional Surgery
Published
2026-04-24
DOI
https://doi.org/10.1136/jnis-2026-025042
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early real world experience with the CREDO heal stent for elective treatment of intracranial atherosclerotic disease

Daulet Suieumbetov, Nurzhan Suleimankulov, Aiman Maidan, Mynzhylky Berdikhojayev et al.
Journal of NeuroInterventional Surgery
Cerebrovascular and Carotid Artery Diseases
article

Early real world experience with the CREDO heal stent for elective treatment of intracranial atherosclerotic disease

Daulet Suieumbetov, Nurzhan Suleimankulov, Aiman Maidan, Mynzhylky Berdikhojayev, I.K. Mussabekov, Shayakhmet Makhanbetkhan, Marat Sarshayev, Abzal Zhumabekov, Maxat Mussabekov, Askerbek Sadvakassov, Rauan Aiteli
article en

Abstract

BACKGROUND: Intracranial atherosclerotic disease (ICAD) is a major cause of ischemic stroke and transient ischemic attack, particularly in Asian populations. Despite best medical therapy, symptomatic ICAD carries a substantial risk of recurrent ischemia. OBJECTIVE: To evaluate the safety and feasibility of the fibrin-heparin coated CREDO heal stent for the treatment of symptomatic high grade ICAD in routine clinical practice. METHODS: This retrospective observational case series included patients with symptomatic intracranial stenosis ≥70% treated with the CREDO heal stent. All patients were receiving best medical therapy and had at least one qualifying ischemic event. The primary safety endpoint was stroke, intracranial hemorrhage, or death within 30 days. Secondary endpoints included technical success, angiographic patency, recurrent ischemic events, and functional outcomes measured by the modified Rankin Scale (mRS). Clinical follow-up occurred at discharge, and at 30, 90, and 180 days, with CT angiography at 90 days and DSA at 180 days. RESULTS: Forty-five patients (78% men; mean age 64.8 years) were treated. Technical success was achieved in all cases, with stenosis reduced from 84.5% to ≤30%. No stroke, intracranial hemorrhage, or death occurred within 30 days. Clinical follow-up was complete in all patients at discharge, and at 90 days and 180 days. Imaging follow-up was available in 41 patients at 90 days and in all patients at 180 days, with no angiographic restenosis or stent thrombosis observed. Favorable functional outcome (mRS score ≤2) was observed in all patients at 6 months. CONCLUSION: In this retrospective series, elective percutaneous transluminal angioplasty and stenting using the CREDO heal stent appeared feasible and showed no major complications in this selected cohort.

Journal of NeuroInterventional Surgery
Almaty Management University (KZ), University of International Business (KZ), National Nuclear Center of the Republic of Kazakhstan (KZ), Astana Medical University (KZ), International Information Technologies University (KZ), Instituto de Neurología de Buenos Aires (AR)
Good health and well-being
Openalex Percentile: Top 8%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.