AI-assisted versus fully automated volumetry for hemorrhage quantification in spontaneous ICH with ventricular extension: A multi-center study

Background: Spontaneous intracerebral hemorrhage (sICH) with intraventricular hemorrhage (IVH) extension is a neurological emergency associated with high mortality, where separate quantification of intraparenchymal hemorrhage (IPH) and IVH volumes is essential for risk stratification and treatment decisions. While commercial artificial intelligence (AI) tools increasingly promise to automate this task, head-to-head comparisons of their separate volumetric accuracy and the clinical utility of AI-assisted correction workflows remain poorly characterized. Methods: In this retrospective multicenter diagnostic accuracy study, 189 sICH patients with IVH extension from seven institutions in China were included. Non-contrast CT scans were analyzed by two commercial AI platforms: Vendor A (uAI-HematomaCare, U-Net-based) and Vendor B (Strokedoc, Trans-UNet-based). A blinded AI-assisted manual correction workflow performed by two senior neuroradiologists established the reference standard. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis, with predefined clinical thresholds of ±6 mL for IPH and ±2 mL for IVH. Processing times were compared. Results: Both AI platforms achieved excellent ICC for IPH (Vendor A: 0.979; Vendor B: 0.991) and good-to-excellent ICC for IVH (Vendor A: 0.855; Vendor B: 0.935) versus the reference standard. However, Bland-Altman analysis revealed that 95% limits of agreement for both AI systems exceeded predefined clinical thresholds for both compartments (IPH: Vendor A -9.96-9.08 mL; Vendor B -6.84-5.04 mL; IVH: Vendor A -7.02-7.52 mL; Vendor B -5.18-4.39 mL), indicating clinically significant individual-level errors. In contrast, the AI-assisted manual correction workflow achieved near-perfect inter-rater reproducibility (ICC >0.99 for both compartments) with 95% limits of agreement entirely within acceptable thresholds, completing corrections in approximately one minute. Automated processing was 65-75% faster than manual correction. Conclusions: Fully automated AI volumetry for sICH with IVH demonstrates high group-level correlation but may produce individual errors exceeding clinically acceptable ranges for treatment decisions. An 'AI-assisted human correction' collaborative model achieves clinical-grade accuracy within approximately one minute and represents the optimal current practice pathway for integrating AI into acute stroke precise volume measurement.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology Open
Published
2026-04-25
DOI
https://doi.org/10.1016/j.ejro.2026.100754
Primary Topic
Intracerebral and Subarachnoid Hemorrhage Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-assisted versus fully automated volumetry for hemorrhage quantification in spontaneous ICH with ventricular extension: A multi-center study

Xiqing Deng, Shengwu Duan, Linan Hu, Can Yin et al.
European Journal of Radiology Open
Intracerebral and Subarachnoid Hemorrhage Research
article

AI-assisted versus fully automated volumetry for hemorrhage quantification in spontaneous ICH with ventricular extension: A multi-center study

Xiqing Deng, Shengwu Duan, Linan Hu, Can Yin, Donglin Xiao
article en

Abstract

Background: Spontaneous intracerebral hemorrhage (sICH) with intraventricular hemorrhage (IVH) extension is a neurological emergency associated with high mortality, where separate quantification of intraparenchymal hemorrhage (IPH) and IVH volumes is essential for risk stratification and treatment decisions. While commercial artificial intelligence (AI) tools increasingly promise to automate this task, head-to-head comparisons of their separate volumetric accuracy and the clinical utility of AI-assisted correction workflows remain poorly characterized. Methods: In this retrospective multicenter diagnostic accuracy study, 189 sICH patients with IVH extension from seven institutions in China were included. Non-contrast CT scans were analyzed by two commercial AI platforms: Vendor A (uAI-HematomaCare, U-Net-based) and Vendor B (Strokedoc, Trans-UNet-based). A blinded AI-assisted manual correction workflow performed by two senior neuroradiologists established the reference standard. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis, with predefined clinical thresholds of ±6 mL for IPH and ±2 mL for IVH. Processing times were compared. Results: Both AI platforms achieved excellent ICC for IPH (Vendor A: 0.979; Vendor B: 0.991) and good-to-excellent ICC for IVH (Vendor A: 0.855; Vendor B: 0.935) versus the reference standard. However, Bland-Altman analysis revealed that 95% limits of agreement for both AI systems exceeded predefined clinical thresholds for both compartments (IPH: Vendor A -9.96-9.08 mL; Vendor B -6.84-5.04 mL; IVH: Vendor A -7.02-7.52 mL; Vendor B -5.18-4.39 mL), indicating clinically significant individual-level errors. In contrast, the AI-assisted manual correction workflow achieved near-perfect inter-rater reproducibility (ICC >0.99 for both compartments) with 95% limits of agreement entirely within acceptable thresholds, completing corrections in approximately one minute. Automated processing was 65-75% faster than manual correction. Conclusions: Fully automated AI volumetry for sICH with IVH demonstrates high group-level correlation but may produce individual errors exceeding clinically acceptable ranges for treatment decisions. An 'AI-assisted human correction' collaborative model achieves clinical-grade accuracy within approximately one minute and represents the optimal current practice pathway for integrating AI into acute stroke precise volume measurement.

European Journal of Radiology OpenVol. 16
Central South University (CN), Zhuzhou Central Hospital (CN)
Zero hunger
Openalex Percentile: Top 9%
Intracerebral and Subarachnoid Hemorrhage Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.