Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard

To compare the diagnostic performance of photon-counting–detector CT (PCD-CT) and dual-energy CT (DECT) perfusion maps against ventilation–perfusion (V/Q) SPECT/CT as reference standard across diverse clinical indications, and to provide quantitative iodine density reference values. This retrospective study included two independent cohorts who underwent V/Q SPECT/CT and either PCD-CT or DECT. Lobar perfusion was assessed on each modality by two blinded readers with consensus serving as the reference for inter-reader agreement. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were calculated using V/Q SPECT/CT as the reference standard. Iodine density was measured using standardized regions of interest placed in normally perfused and hypoperfused lobes. Inter-reader agreement was evaluated using Cohen’s κ. Statistical comparisons were performed using paired or unpaired tests as appropriate, with significance set at p < 0.05. PCD-CT demonstrated an accuracy of 0.85, sensitivity of 0.71, specificity of 0.97, and κ of 0.80. DECT demonstrated an accuracy of 0.89, sensitivity of 0.52, specificity of 0.97, and κ of 0.59. Differences in diagnostic performance between PCD-CT and DECT were not statistically significant. Iodine density was significantly higher in normally perfused lung compared with perfusion defects for both PCD-CT (2.10±0.29 vs 0.40±0.18 mg/mL; p < 0.001) and DECT (2.30±0.29 vs 0.49±0.17 mg/mL; p < 0.001). Both PCD-CT and DECT provide high diagnostic accuracy for detecting lobar perfusion defects, with PCD-CT demonstrating higher inter-reader agreement. This study provides the first quantitative iodine reference values for PCD-CT pulmonary perfusion, supporting its potential as a robust functional complement to conventional CTPA.

Authors

Institutions

Publication Details

Journal
Emergency Radiology
Published
2026-04-25
DOI
https://doi.org/10.1007/s10140-026-02479-x
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard

Dhiraj Baruah, Ismail Kabakus, Saeed Elojeimy, Jeremy R. Burt et al.
Emergency Radiology
Advanced X-ray and CT Imaging
article

Comparative accuracy of photon-counting and dual energy CT pulmonary angiography perfusion mapping using V/Q scans as reference standard

Dhiraj Baruah, Ismail Kabakus, Saeed Elojeimy, Jeremy R. Burt, César López Rodríguez, Ian Mencken, Jordan H. Chamberlin, Alexis Ogbonna
article en

Abstract

To compare the diagnostic performance of photon-counting–detector CT (PCD-CT) and dual-energy CT (DECT) perfusion maps against ventilation–perfusion (V/Q) SPECT/CT as reference standard across diverse clinical indications, and to provide quantitative iodine density reference values. This retrospective study included two independent cohorts who underwent V/Q SPECT/CT and either PCD-CT or DECT. Lobar perfusion was assessed on each modality by two blinded readers with consensus serving as the reference for inter-reader agreement. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were calculated using V/Q SPECT/CT as the reference standard. Iodine density was measured using standardized regions of interest placed in normally perfused and hypoperfused lobes. Inter-reader agreement was evaluated using Cohen’s κ. Statistical comparisons were performed using paired or unpaired tests as appropriate, with significance set at p < 0.05. PCD-CT demonstrated an accuracy of 0.85, sensitivity of 0.71, specificity of 0.97, and κ of 0.80. DECT demonstrated an accuracy of 0.89, sensitivity of 0.52, specificity of 0.97, and κ of 0.59. Differences in diagnostic performance between PCD-CT and DECT were not statistically significant. Iodine density was significantly higher in normally perfused lung compared with perfusion defects for both PCD-CT (2.10±0.29 vs 0.40±0.18 mg/mL; p < 0.001) and DECT (2.30±0.29 vs 0.49±0.17 mg/mL; p < 0.001). Both PCD-CT and DECT provide high diagnostic accuracy for detecting lobar perfusion defects, with PCD-CT demonstrating higher inter-reader agreement. This study provides the first quantitative iodine reference values for PCD-CT pulmonary perfusion, supporting its potential as a robust functional complement to conventional CTPA.

Emergency Radiology
Medical University of South Carolina (US), University of Utah (US)
Medical University of South Carolina
Affordable and clean energy
Openalex Percentile: Top 10%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.