Validation and comparative analysis of a contemporary non-contact corneal aesthesiometer

Background: Corneal sensitivity is a key indicator of ocular surface health. This prospective, cross-sectional study evaluated agreement between corneal sensitivity thresholds obtained from equivalent stimulus settings on a contemporary, enhanced dual-temperature non-contact corneal aesthesiometer (NCCA) and a previously validated (standard) device. Methods: Central corneal sensitivity thresholds were measured in the right eyes of healthy participants using both devices. Participants with previous ocular surgery, laser treatment, trauma, contact lens wear, diabetes, or peripheral neuropathy were excluded. Sensitivity thresholds were determined using a forced-response, double-staircase protocol. Inter-device agreement was assessed using Bland–Altman analysis, and consistency was assessed using intraclass correlation coefficients. Results: Median corneal sensitivity thresholds in 51 healthy participants (32 female, 19 male; mean age: 33 ± 14 years) did not differ between enhanced (0.23 [0.18 to 0.38]) and standard (0.25 [0.15 to 0.35]) NCCA instruments (p = 0.73). Bland–Altman analysis demonstrated moderate inter-device agreement, with a mean difference of −0.01 mbar (95% limits of agreement: −0.41 to 0.39 mbar). Linear regression analysis identified greater measurement discrepancies at higher thresholds (p < 0.05), indicating greater variability in individuals with reduced corneal sensitivity. Conclusions: The enhanced NCCA yields reliable corneal sensitivity measures for a room-temperature stimulus and acceptable agreement with the existing (standard) model.

Authors

Publication Details

Journal
Institutional Repository (IHS Vienna)
Published
2026-04-20
DOI
https://doi.org/10.26041/fhnw-16122
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and comparative analysis of a contemporary non-contact corneal aesthesiometer

Alex Müntz, Ally L. Xue, Jennifer P. Craig, Laura Elizabeth Downie et al.
Institutional Repository (IHS Vienna)
Ocular Surface and Contact Lens
article

Validation and comparative analysis of a contemporary non-contact corneal aesthesiometer

Alex Müntz, Ally L. Xue, Jennifer P. Craig, Laura Elizabeth Downie, S. Misra, Catherine Jennings, Dian Zhuang, Alexis Ceecee Britten-Jones
article en

Abstract

Background: Corneal sensitivity is a key indicator of ocular surface health. This prospective, cross-sectional study evaluated agreement between corneal sensitivity thresholds obtained from equivalent stimulus settings on a contemporary, enhanced dual-temperature non-contact corneal aesthesiometer (NCCA) and a previously validated (standard) device. Methods: Central corneal sensitivity thresholds were measured in the right eyes of healthy participants using both devices. Participants with previous ocular surgery, laser treatment, trauma, contact lens wear, diabetes, or peripheral neuropathy were excluded. Sensitivity thresholds were determined using a forced-response, double-staircase protocol. Inter-device agreement was assessed using Bland–Altman analysis, and consistency was assessed using intraclass correlation coefficients. Results: Median corneal sensitivity thresholds in 51 healthy participants (32 female, 19 male; mean age: 33 ± 14 years) did not differ between enhanced (0.23 [0.18 to 0.38]) and standard (0.25 [0.15 to 0.35]) NCCA instruments (p = 0.73). Bland–Altman analysis demonstrated moderate inter-device agreement, with a mean difference of −0.01 mbar (95% limits of agreement: −0.41 to 0.39 mbar). Linear regression analysis identified greater measurement discrepancies at higher thresholds (p < 0.05), indicating greater variability in individuals with reduced corneal sensitivity. Conclusions: The enhanced NCCA yields reliable corneal sensitivity measures for a room-temperature stimulus and acceptable agreement with the existing (standard) model.

Institutional Repository (IHS Vienna)
Openalex Percentile: Top 10%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.