Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View

BACKGROUND: Murray-law based quantitative flow ratio (μFR) enables rapid fractional flow reserve (FFR) computation from invasive coronary angiography (ICA) using a single projection, but the influence of plaque eccentricity on its diagnostic accuracy remains unclear. AIMS: To investigate whether eccentric plaque impacts the diagnostic accuracy of single-view μFR. METHODS: We performed a blinded analysis of the prospective CAREER trial database, enrolling patients with 30%-90% diameter stenosis on coronary computed tomography angiography (CCTA) who underwent μFR and FFR assessments within 30 days. ICA were acquired using standardized, protocol-specified projections. CCTA images were analyzed using dedicated software and co-registered with ICA. For each μFR-identified lesion, plaque eccentricity index (PEI) and lumen asymmetry index (LAI) were computed across all cross-sections and averaged to yield PEI and LAI per-vessel. Vessels were classified as having eccentric/concentric plaques using median PEI, and subclassified as having asymmetric/symmetric lumens using median LAI. RESULTS: Among 231 vessels (201 patients), median μFR and FFR were 0.84 and 0.83, respectively. PEI and LAI moderately correlated (ρ = 0.46, p < 0.001). Limits of agreement between μFR and FFR were wider in eccentric versus concentric plaques (standard deviation 0.08 vs. 0.06; p = 0.003), mainly driven by presence of asymmetric lumens (standard deviation 0.09 vs. 0.06 in symmetric lumens; p = 0.029). μFR had comparable AUC for predicting FFR ≤ 0.80 between concentric plaques and eccentric plaques with symmetric lumens (0.94 vs. 0.95; p = 0.909). CONCLUSIONS: The diagnostic accuracy of single-view μFR, derived from standardized angiographic projections, was moderately affected by eccentric plaques, with the effect primarily attributable to asymmetric lumens.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-04-22
DOI
https://doi.org/10.1002/ccd.70642
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View

G Y Li, William C. Wijns, Tingwen Weng, M C Li et al.
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View

G Y Li, William C. Wijns, Tingwen Weng, M C Li, Min Pan, Daixin Ding, S Guan, Xiaoling Wang, Xinkai Qu, Ruilin He, Shengxian Tu, Xinyi Yang
article en

Abstract

BACKGROUND: Murray-law based quantitative flow ratio (μFR) enables rapid fractional flow reserve (FFR) computation from invasive coronary angiography (ICA) using a single projection, but the influence of plaque eccentricity on its diagnostic accuracy remains unclear. AIMS: To investigate whether eccentric plaque impacts the diagnostic accuracy of single-view μFR. METHODS: We performed a blinded analysis of the prospective CAREER trial database, enrolling patients with 30%-90% diameter stenosis on coronary computed tomography angiography (CCTA) who underwent μFR and FFR assessments within 30 days. ICA were acquired using standardized, protocol-specified projections. CCTA images were analyzed using dedicated software and co-registered with ICA. For each μFR-identified lesion, plaque eccentricity index (PEI) and lumen asymmetry index (LAI) were computed across all cross-sections and averaged to yield PEI and LAI per-vessel. Vessels were classified as having eccentric/concentric plaques using median PEI, and subclassified as having asymmetric/symmetric lumens using median LAI. RESULTS: Among 231 vessels (201 patients), median μFR and FFR were 0.84 and 0.83, respectively. PEI and LAI moderately correlated (ρ = 0.46, p < 0.001). Limits of agreement between μFR and FFR were wider in eccentric versus concentric plaques (standard deviation 0.08 vs. 0.06; p = 0.003), mainly driven by presence of asymmetric lumens (standard deviation 0.09 vs. 0.06 in symmetric lumens; p = 0.029). μFR had comparable AUC for predicting FFR ≤ 0.80 between concentric plaques and eccentric plaques with symmetric lumens (0.94 vs. 0.95; p = 0.909). CONCLUSIONS: The diagnostic accuracy of single-view μFR, derived from standardized angiographic projections, was moderately affected by eccentric plaques, with the effect primarily attributable to asymmetric lumens.

Catheterization and Cardiovascular Interventions
Shanghai Jiao Tong University (CN), Fudan University (CN), Renji Hospital (CN), Shanghai Chest Hospital (CN), Huadong Hospital (CN), Sanya Central Hospital (CN), Sanya University (CN), The Medical Device (United Kingdom) (GB)
National Natural Science Foundation of China
Openalex Percentile: Top 8%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.