Fast Occupational Upper-Limb Radiation Dose Prediction Using Machine Learning and Monte Carlo Simulation

OBJECTIVE: Interventional procedures expose physicians to scattered radiation, particularly to their upper extremities, posing occupational health risks. Existing extremity dosimeters such as TLDs, OSL rings and active personal dosimeters provide limited spatial information, exhibit angular and energy dependence and offer little or no real-time feedback. This study develops machine learning models to estimate radiation dose values at discrete upper-limb locations using Monte Carlo-derived data and procedurespecific parameters. APPROACH: A dataset of 10,000 Monte Carlo dose maps was generated under varied clinical and geometric conditions. After log-transformation and normalization, several machine learning models, including deep neural networks and treebased regressor, were trained and assessed using five-fold cross-validation. Mean absolute error and relative error were evaluated on the original dose scale, and an ensemble of the three best-performing models was constructed to improve robustness. MAIN RESULTS: The ensemble consistently outperformed individual models, achieving an average relative error of 3.69 % and demonstrating stable performance across anatomical regions and dose levels. Highest accuracy was obtained for standard beam geometries, whereas larger discrepancies occurred in extreme configurations with steep dose gradients. Predicted dose patterns were consistent with the expected distributions across the upper-limb regions. SIGNIFICANCE: The findings demonstrate the feasibility of machine learning-based extremity dose estimation in interventional environments. The proposed ensemble provides a rapid (around 10 ms), scalable alternative to full Monte Carlo simulations, enabling near real-time predictions of upper-limb occupational dose and supporting optimization of radiation protection practices in image-guided procedures.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-04-23
DOI
https://doi.org/10.1088/1361-6498/ae63da
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Occupational Upper-Limb Radiation Dose Prediction Using Machine Learning and Monte Carlo Simulation

Hussein Harb, Kamilia Taguelmimt, Julien Bert, Didier Benoit et al.
Journal of Radiological Protection
Radiation Dose and Imaging
article

Fast Occupational Upper-Limb Radiation Dose Prediction Using Machine Learning and Monte Carlo Simulation

Hussein Harb, Kamilia Taguelmimt, Julien Bert, Didier Benoit, Chi-Hieu Pham, Bahaa Nasr
article en

Abstract

OBJECTIVE: Interventional procedures expose physicians to scattered radiation, particularly to their upper extremities, posing occupational health risks. Existing extremity dosimeters such as TLDs, OSL rings and active personal dosimeters provide limited spatial information, exhibit angular and energy dependence and offer little or no real-time feedback. This study develops machine learning models to estimate radiation dose values at discrete upper-limb locations using Monte Carlo-derived data and procedurespecific parameters. APPROACH: A dataset of 10,000 Monte Carlo dose maps was generated under varied clinical and geometric conditions. After log-transformation and normalization, several machine learning models, including deep neural networks and treebased regressor, were trained and assessed using five-fold cross-validation. Mean absolute error and relative error were evaluated on the original dose scale, and an ensemble of the three best-performing models was constructed to improve robustness. MAIN RESULTS: The ensemble consistently outperformed individual models, achieving an average relative error of 3.69 % and demonstrating stable performance across anatomical regions and dose levels. Highest accuracy was obtained for standard beam geometries, whereas larger discrepancies occurred in extreme configurations with steep dose gradients. Predicted dose patterns were consistent with the expected distributions across the upper-limb regions. SIGNIFICANCE: The findings demonstrate the feasibility of machine learning-based extremity dose estimation in interventional environments. The proposed ensemble provides a rapid (around 10 ms), scalable alternative to full Monte Carlo simulations, enabling near real-time predictions of upper-limb occupational dose and supporting optimization of radiation protection practices in image-guided procedures.

Journal of Radiological Protection
Inserm (FR), Université de Bretagne Occidentale (FR), Laboratoire des Sciences et Techniques de l’Information de la Communication et de la Connaissance (FR), Laboratoire de Traitement de l'Information Médicale (FR)
Agence Nationale de la Recherche, Université de Bretagne Occidentale, Région Bretagne
Openalex Percentile: Top 8%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.