Photon-recycling lensless fluorometer

Fluorometers typically employ multiple lenses and a single-pass optical geometry. We present a lensless fluorometer with a simple reflective sample chamber to recycle the unused excitation photons by reflecting them back into the sample volume while simultaneously redirecting emission photons toward the detector, thereby significantly enhancing the signal. By using commonly available aluminum bars, we experimentally achieve a 4.3× signal enhancement compared to a single-pass chamber in a lensless configuration. Combined with the documented 2× advantage of lensless systems, this design is projected to outperform standard lensed fluorometers by more than 8×. The enhanced performance allows for an 8× reduction in the excitation power while maintaining the required sub-parts-per-billion detection limit for tryptophan-like-fluorescence in drinking water. The power reduction significantly simplifies thermal and power management, which is essential for in-field and future handheld operation. We present a theoretical analysis that is supported by experimental results to validate this approach. Our system demonstrates a highly sensitive, power-efficient, and simplified platform for fluorescence measurement, opening new avenues for handheld and remote water quality sensing.

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America B
Published
2026-04-23
DOI
https://doi.org/10.1364/josab.588579
Primary Topic
Advanced optical system design
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-recycling lensless fluorometer

Rijan Maharjan, Ashim Dhakal, Rajin Pradhan, Sharad Timilsina et al.
Journal of the Optical Society of America B
Advanced optical system design
article

Photon-recycling lensless fluorometer

Rijan Maharjan, Ashim Dhakal, Rajin Pradhan, Sharad Timilsina, Asim Maharjan, Emiliano Martins, Thomas Krauss, Paru Hang Rai
article en

Abstract

Fluorometers typically employ multiple lenses and a single-pass optical geometry. We present a lensless fluorometer with a simple reflective sample chamber to recycle the unused excitation photons by reflecting them back into the sample volume while simultaneously redirecting emission photons toward the detector, thereby significantly enhancing the signal. By using commonly available aluminum bars, we experimentally achieve a 4.3× signal enhancement compared to a single-pass chamber in a lensless configuration. Combined with the documented 2× advantage of lensless systems, this design is projected to outperform standard lensed fluorometers by more than 8×. The enhanced performance allows for an 8× reduction in the excitation power while maintaining the required sub-parts-per-billion detection limit for tryptophan-like-fluorescence in drinking water. The power reduction significantly simplifies thermal and power management, which is essential for in-field and future handheld operation. We present a theoretical analysis that is supported by experimental results to validate this approach. Our system demonstrates a highly sensitive, power-efficient, and simplified platform for fluorescence measurement, opening new avenues for handheld and remote water quality sensing.

Journal of the Optical Society of America BVol. 43(8)
University of York (GB)
Optica Foundation
Clean water and sanitation
Openalex Percentile: Top 21%
Advanced optical system design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.