Diagnostic Accuracy of Urine Flow Cytometry (UF) in Urinary Tract Infection (UTI) Detection and Management: A Systematic Review and Meta-Analysis

Background: Urinary tract infections (UTIs) are prevalent bacterial infections associated with significant morbidity and healthcare burden. Traditional diagnosis relies on urine culture, which is limited by long turnaround times and potential contamination. Automated urine flow cytometry, particularly the UF-5000 (Sysmex Corporation, Kobe, Japan), offers rapid and precise screening through bacterial and white blood cell (WBC) quantification. This systematic review and meta-analysis evaluates the diagnostic accuracy of the UF-5000 for UTI screening. Methods: We searched PubMed, Embase, Science Direct, and Web of Science for studies assessing the UF-5000’s performance, including sensitivity and specificity, with a minimum sample size of 40 and at least 10 UTI cases. Quality assessment was performed using QUADAS-2. Pooled estimates for sensitivity, specificity, and agreement (kappa) were calculated using random-effects models. Results: Eighteen studies, encompassing 25,337 samples, were included in the analysis. Pooled sensitivity and specificity for bacterial count (nine studies) were 0.927 (95% CI, 0.872–0.959) and 0.751 (95% CI, 0.558–0.878), respectively. For WBC count (four studies), sensitivity was 0.897 (95% CI, 0.755–0.961) and specificity was 0.600 (95% CI, 0.293–0.844). The UF-5000 also demonstrated moderate agreement (pooled kappa 0.52, 95% CI, 0.08–0.79) in distinguishing Gram-negative bacteria. Conclusions: Despite heterogeneity across studies, the UF-5000 demonstrates high diagnostic accuracy, particularly high sensitivity, supporting its role as a useful UTI screening tool to rule out infection in clinical settings. The device further provides clinical value through its ability to assist in the differentiation of Gram-negative bacteria.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-04-23
DOI
https://doi.org/10.3390/diagnostics16091275
Primary Topic
Urinary Tract Infections Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Urine Flow Cytometry (UF) in Urinary Tract Infection (UTI) Detection and Management: A Systematic Review and Meta-Analysis

Shin Mei Wong, Shang‐Jen Chang, Chung-You Tsai, Jeff Shih-Chieh Chueh et al.
Diagnostics
Urinary Tract Infections Management
article

Diagnostic Accuracy of Urine Flow Cytometry (UF) in Urinary Tract Infection (UTI) Detection and Management: A Systematic Review and Meta-Analysis

Shin Mei Wong, Shang‐Jen Chang, Chung-You Tsai, Jeff Shih-Chieh Chueh, Kai-Wei Chang
article en

Abstract

Background: Urinary tract infections (UTIs) are prevalent bacterial infections associated with significant morbidity and healthcare burden. Traditional diagnosis relies on urine culture, which is limited by long turnaround times and potential contamination. Automated urine flow cytometry, particularly the UF-5000 (Sysmex Corporation, Kobe, Japan), offers rapid and precise screening through bacterial and white blood cell (WBC) quantification. This systematic review and meta-analysis evaluates the diagnostic accuracy of the UF-5000 for UTI screening. Methods: We searched PubMed, Embase, Science Direct, and Web of Science for studies assessing the UF-5000’s performance, including sensitivity and specificity, with a minimum sample size of 40 and at least 10 UTI cases. Quality assessment was performed using QUADAS-2. Pooled estimates for sensitivity, specificity, and agreement (kappa) were calculated using random-effects models. Results: Eighteen studies, encompassing 25,337 samples, were included in the analysis. Pooled sensitivity and specificity for bacterial count (nine studies) were 0.927 (95% CI, 0.872–0.959) and 0.751 (95% CI, 0.558–0.878), respectively. For WBC count (four studies), sensitivity was 0.897 (95% CI, 0.755–0.961) and specificity was 0.600 (95% CI, 0.293–0.844). The UF-5000 also demonstrated moderate agreement (pooled kappa 0.52, 95% CI, 0.08–0.79) in distinguishing Gram-negative bacteria. Conclusions: Despite heterogeneity across studies, the UF-5000 demonstrates high diagnostic accuracy, particularly high sensitivity, supporting its role as a useful UTI screening tool to rule out infection in clinical settings. The device further provides clinical value through its ability to assist in the differentiation of Gram-negative bacteria.

DiagnosticsVol. 16(9)
Far Eastern Memorial Hospital (TW), National Taiwan University Hospital (TW), Yuan Ze University (TW)
Sysmex Corporation, Far Eastern Memorial Hospital
Good health and well-being
Openalex Percentile: Top 8%
Urinary Tract Infections Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.