Trueness of fully guided static computer-assisted implant surgery for immediate implant placement in premolar and molar sites, an observational analysis

To quantify the trueness of fully guided static computer-assisted implant surgery (s-CAIS) for immediate implant placement in premolar and molar sites, and to explore whether implant and workflow parameters are associated with angular deviation. In this observational analysis of a cohort derived from a previously randomized clinical trial, 49 implants were placed immediately after extraction using a fully guided s-CAIS workflow. Preoperative planning data were compared with a 3-month postoperative cone-beam computed tomography (CBCT) scan using a manufacturer-developed analysis module. Trueness was assessed as 3D, vertical, and lateral deviation at the implant platform, as well as angular deviation. Between group comparisons were interpreted as exploratory. In 49 implants (25 maxilla, 24 mandible; 34 molars, 15 premolars), mean (standard deviation, SD) platform deviations were 0.92 (0.40) mm for 3D deviation, − 0.26 (0.63) mm for vertical deviation (negative indicates shallower placement), and 0.66 (0.33) mm for lateral deviation. Mean (SD) angular deviation was 3.77 (2.28) degrees. In exploratory analyses, angular deviation differed between implant length groups (p = 0.010). Categories with a single implant in sleeve height (H2) and drill length (16 mm) were reported descriptively only. In this observational cohort, fully guided s-CAIS yielded platform-based trueness and angular deviation values for immediate implant placement in premolar and molar sites that were within ranges reported in the guided surgery literature. Findings on factors associated with angular deviation should be interpreted as exploratory and require confirmation in further studies. Provides in vivo trueness estimates for fully guided implant placement performed immediately after extraction in premolar and molar sites.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-04-22
DOI
https://doi.org/10.1186/s12903-026-08356-w
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trueness of fully guided static computer-assisted implant surgery for immediate implant placement in premolar and molar sites, an observational analysis

Algirdas Puišys, Dainius Razukevičius, Samuel Akhondi, Vitālijs Gnusins et al.
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Trueness of fully guided static computer-assisted implant surgery for immediate implant placement in premolar and molar sites, an observational analysis

Algirdas Puišys, Dainius Razukevičius, Samuel Akhondi, Vitālijs Gnusins, German O. Gallucci, João Afonso
article en

Abstract

To quantify the trueness of fully guided static computer-assisted implant surgery (s-CAIS) for immediate implant placement in premolar and molar sites, and to explore whether implant and workflow parameters are associated with angular deviation. In this observational analysis of a cohort derived from a previously randomized clinical trial, 49 implants were placed immediately after extraction using a fully guided s-CAIS workflow. Preoperative planning data were compared with a 3-month postoperative cone-beam computed tomography (CBCT) scan using a manufacturer-developed analysis module. Trueness was assessed as 3D, vertical, and lateral deviation at the implant platform, as well as angular deviation. Between group comparisons were interpreted as exploratory. In 49 implants (25 maxilla, 24 mandible; 34 molars, 15 premolars), mean (standard deviation, SD) platform deviations were 0.92 (0.40) mm for 3D deviation, − 0.26 (0.63) mm for vertical deviation (negative indicates shallower placement), and 0.66 (0.33) mm for lateral deviation. Mean (SD) angular deviation was 3.77 (2.28) degrees. In exploratory analyses, angular deviation differed between implant length groups (p = 0.010). Categories with a single implant in sleeve height (H2) and drill length (16 mm) were reported descriptively only. In this observational cohort, fully guided s-CAIS yielded platform-based trueness and angular deviation values for immediate implant placement in premolar and molar sites that were within ranges reported in the guided surgery literature. Findings on factors associated with angular deviation should be interpreted as exploratory and require confirmation in further studies. Provides in vivo trueness estimates for fully guided implant placement performed immediately after extraction in premolar and molar sites.

BMC Oral Health
Harvard University (US), Hospital of Lithuanian University of Health Sciences Kaunas Clinics (LT), Samueli Institute (US), State Education Development Agency (LV), Medical University of Vienna (AT)
Openalex Percentile: Top 5%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.