Proton microbeam characterization using a single-particle scintillator

OBJECTIVE: To develop a simple and high-resolution method for measuring both the local dose and lateral beam width of a microproton beam using light emission from a single micron-sized scintillator particle. APPROACH: We used ZnS:Ag (silver-activated zinc sulfide) scintillator powder, known for its favorable dose response and peak emission at 450 nm. Proton microbeams (3.4 MeV) were delivered using the Single-Particle Irradiation system to Cell (SPICE) at the National Institute for Quantum and Radiological Science and Technology. The scintillator powder was dispersed on a thin film placed over a cell culture dish, and the emission from individual particles was recorded using a microscope-coupled camera. By scanning the proton beam in 400 nm steps across the particles, we measured variations in light intensity to evaluate both irradiation dose and beam profile. MAIN RESULTS: The luminescence intensity increased linearly with irradiation time and varied consistently with beam position relative to the particle center. Despite the particle diameter exceeding the beam width, emission modulation enabled precise localization of the beam center. Measured lateral beam widths using four particles with diameters of approximately 8 μm were 1.9 ± 0.3 μm in the X direction and 1.8 ± 0.4 μm in the Y direction, demonstrating sub-micron resolution beyond the imaging system's pixel size. SIGNIFICANCE: This method enables simultaneous estimation of dose and beam width using a single scintillator particle, without requiring complex microdosimetric equipment. It provides a practical and accurate tool for microbeam characterization, contributing to improved dosimetry and targeting precision in radiobiological research at the cellular and subcellular scale. By exploiting emission modulation within a single scintillator particle, beam profiles can be reconstructed with spatial precision beyond the optical pixel resolution.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-04-22
DOI
https://doi.org/10.1088/1361-6560/ae63a1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proton microbeam characterization using a single-particle scintillator

Katsunori Yogo, Hiroshi Yasuda, Kazutaka Akiyoshi, D. Ohsawa et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

Proton microbeam characterization using a single-particle scintillator

Katsunori Yogo, Hiroshi Yasuda, Kazutaka Akiyoshi, D. Ohsawa, Ryu Okada, Seiichi Yamamoto, Masao Yoshino, Tsukasa Torimoto, Tatsuya Kameyama
article en

Abstract

OBJECTIVE: To develop a simple and high-resolution method for measuring both the local dose and lateral beam width of a microproton beam using light emission from a single micron-sized scintillator particle. APPROACH: We used ZnS:Ag (silver-activated zinc sulfide) scintillator powder, known for its favorable dose response and peak emission at 450 nm. Proton microbeams (3.4 MeV) were delivered using the Single-Particle Irradiation system to Cell (SPICE) at the National Institute for Quantum and Radiological Science and Technology. The scintillator powder was dispersed on a thin film placed over a cell culture dish, and the emission from individual particles was recorded using a microscope-coupled camera. By scanning the proton beam in 400 nm steps across the particles, we measured variations in light intensity to evaluate both irradiation dose and beam profile. MAIN RESULTS: The luminescence intensity increased linearly with irradiation time and varied consistently with beam position relative to the particle center. Despite the particle diameter exceeding the beam width, emission modulation enabled precise localization of the beam center. Measured lateral beam widths using four particles with diameters of approximately 8 μm were 1.9 ± 0.3 μm in the X direction and 1.8 ± 0.4 μm in the Y direction, demonstrating sub-micron resolution beyond the imaging system's pixel size. SIGNIFICANCE: This method enables simultaneous estimation of dose and beam width using a single scintillator particle, without requiring complex microdosimetric equipment. It provides a practical and accurate tool for microbeam characterization, contributing to improved dosimetry and targeting precision in radiobiological research at the cellular and subcellular scale. By exploiting emission modulation within a single scintillator particle, beam profiles can be reconstructed with spatial precision beyond the optical pixel resolution.

Physics in Medicine and Biology
Hiroshima University (JP), Waseda University (JP), Tohoku University (JP), National Institutes for Quantum Science and Technology (JP), Nagoya University (JP)
Hiroshima University, Japan Society for the Promotion of Science
Openalex Percentile: Top 10%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.