COMP Report: Patient‐specific quality assurance practices in Canadian radiotherapy—results from a national survey

Patient-specific quality assurance (PSQA) is an essential component of modern radiotherapy, ensuring safe and accurate delivery of increasingly complex treatments. Given its resource-intensive nature and the availability of evolving approaches, examining how PSQA is implemented and optimized across Canada is important to inform best practices. This study aimed to characterize the current landscape of PSQA practice across Canadian radiotherapy centers, identify patterns and regional variations, and explore opportunities for future national guidance. A 30-question web-based survey was developed and distributed in March 2024 to all Canadian radiotherapy centers, including satellites. The survey addressed staffing, treatment machines, PSQA tools and methodologies, policies, data analysis, frequency of PSQA, and failure management. Responses were collected in both English and French, de-identified, and analyzed by center size and region (British Columbia, Prairies, Ontario, Quebec, and Atlantic). The survey achieved a 90% response rate (45 of 50 centers). Most centers reported using 3D array detectors, followed by EPID and point detectors. Gamma index analysis was the predominant evaluation method. More than half of participating centers, including 65% of large centers, reported reducing PSQA measurement frequency, citing accumulated local experience rather than external guidance. However, all centers in the Prairies and Atlantic regions reported maintaining full measurement frequency. A vast majority of centers that used delivery log calculations also reported a reduction in measurement frequency, while most centers using EPID did not. Across all regions, selective adoption of recommendations from both Canadian and American guidelines was observed. PSQA practices in Canada are heterogeneous, reflecting local resources, institutional experience, and evolving international recommendations. Given the resource-intensive nature of PSQA and observed variability in practice, these findings highlight the value of developing national guidance tailored to Canadian clinical realities.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-04-21
DOI
https://doi.org/10.1002/acm2.70591
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMP Report: Patient‐specific quality assurance practices in Canadian radiotherapy—results from a national survey

G. Lagmago Kamta, Renée-Xavière Larouche, Nicolas Varfalvy, Philip Wright et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

COMP Report: Patient‐specific quality assurance practices in Canadian radiotherapy—results from a national survey

G. Lagmago Kamta, Renée-Xavière Larouche, Nicolas Varfalvy, Philip Wright, Gordon H. Chan, Richard Lee, Brennen Dobberthien
article en

Abstract

Patient-specific quality assurance (PSQA) is an essential component of modern radiotherapy, ensuring safe and accurate delivery of increasingly complex treatments. Given its resource-intensive nature and the availability of evolving approaches, examining how PSQA is implemented and optimized across Canada is important to inform best practices. This study aimed to characterize the current landscape of PSQA practice across Canadian radiotherapy centers, identify patterns and regional variations, and explore opportunities for future national guidance. A 30-question web-based survey was developed and distributed in March 2024 to all Canadian radiotherapy centers, including satellites. The survey addressed staffing, treatment machines, PSQA tools and methodologies, policies, data analysis, frequency of PSQA, and failure management. Responses were collected in both English and French, de-identified, and analyzed by center size and region (British Columbia, Prairies, Ontario, Quebec, and Atlantic). The survey achieved a 90% response rate (45 of 50 centers). Most centers reported using 3D array detectors, followed by EPID and point detectors. Gamma index analysis was the predominant evaluation method. More than half of participating centers, including 65% of large centers, reported reducing PSQA measurement frequency, citing accumulated local experience rather than external guidance. However, all centers in the Prairies and Atlantic regions reported maintaining full measurement frequency. A vast majority of centers that used delivery log calculations also reported a reduction in measurement frequency, while most centers using EPID did not. Across all regions, selective adoption of recommendations from both Canadian and American guidelines was observed. PSQA practices in Canada are heterogeneous, reflecting local resources, institutional experience, and evolving international recommendations. Given the resource-intensive nature of PSQA and observed variability in practice, these findings highlight the value of developing national guidance tailored to Canadian clinical realities.

Journal of Applied Clinical Medical PhysicsVol. 27(5)
Royal Victoria Regional Health Centre (CA), Juravinski Cancer Centre (CA), Surrey Memorial Hospital (CA), University of Saskatchewan (CA), CancerCare Manitoba (CA), Saskatchewan Cancer Agency (CA), Hôpital Charles-Le Moyne (CA), Hôpital de l'Enfant-Jésus (CA), Centre Hospitalier de l’Université de Montréal (CA)
Openalex Percentile: Top 6%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies