Frequency-Output Autogenerator Gas Transducers and FPGA-Based Multichannel Monitoring System for Smart Biogas Plants in Cloud-Integrated Energy Infrastructures

The rapid development of smart energy infrastructures and renewable energy systems requires advanced sensing solutions that provide high accuracy, expandability, and stability under real operating conditions. However, conventional gas monitoring systems are predominantly based on resistive or voltage-output sensors, which require complex analog front-end circuits and analog-to-digital conversion, leading to increased system complexity, cost, and susceptibility to electromagnetic interference. This paper tackles this limitation by proposing a frequency-domain sensing approach for multichannel monitoring of biogas plant parameters. The objective of this study is to develop and experimentally validate an extendable sensing architecture based on autogenerator microelectronic gas transducers with direct gas concentration–frequency conversion and FPGA-based digital acquisition. The proposed method is grounded in a physical–mathematical model of the space-charge capacitance of gas-sensitive semiconductor structures derived from Poisson’s equation, facilitating analytical formulation of conversion and sensitivity functions. A multichannel FPGA-based measurement system is implemented to process frequency signals without analog conditioning or ADC stages. Experimental validation was performed for CH4 (0–85%), CO2 (0–60%), H2, NH3, and H2S (1–20,000 ppm). The results demonstrate measurement uncertainty within 0.25–0.5%, with sensitivity reaching 350–748 Hz/ppm for H2, 455–750 Hz/ppm for NH3, and 253–375 Hz/ppm for H2S, while methane and carbon dioxide sensitivities reach up to 112 kHz/% and 98.7 kHz/%, respectively. Spectral analysis in the LTE-1800 band confirms improved noise immunity (up to 4.5×) and extended transmission capabilities. A 12-channel FPGA-based monitoring system (RDM-BP-1) with a 1 s sampling interval, IP67 protection, and wireless connectivity is developed and validated. The proposed architecture eliminates analog signal conditioning, reduces hardware complexity, and provides an easily expandable and reliable sensing solution for smart buildings, renewable energy systems, and cloud-integrated energy infrastructures.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-04-22
DOI
https://doi.org/10.3390/electronics15091780
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency-Output Autogenerator Gas Transducers and FPGA-Based Multichannel Monitoring System for Smart Biogas Plants in Cloud-Integrated Energy Infrastructures

Serhii Baraban, Olena O. Semenova, Oleksandr V. Osadchuk, Ярослав Осадчук et al.
Electronics
Gas Sensing Nanomaterials and Sensors
article

Frequency-Output Autogenerator Gas Transducers and FPGA-Based Multichannel Monitoring System for Smart Biogas Plants in Cloud-Integrated Energy Infrastructures

Serhii Baraban, Olena O. Semenova, Oleksandr V. Osadchuk, Ярослав Осадчук, Mariia Baraban, Andrii Semenov
article en

Abstract

The rapid development of smart energy infrastructures and renewable energy systems requires advanced sensing solutions that provide high accuracy, expandability, and stability under real operating conditions. However, conventional gas monitoring systems are predominantly based on resistive or voltage-output sensors, which require complex analog front-end circuits and analog-to-digital conversion, leading to increased system complexity, cost, and susceptibility to electromagnetic interference. This paper tackles this limitation by proposing a frequency-domain sensing approach for multichannel monitoring of biogas plant parameters. The objective of this study is to develop and experimentally validate an extendable sensing architecture based on autogenerator microelectronic gas transducers with direct gas concentration–frequency conversion and FPGA-based digital acquisition. The proposed method is grounded in a physical–mathematical model of the space-charge capacitance of gas-sensitive semiconductor structures derived from Poisson’s equation, facilitating analytical formulation of conversion and sensitivity functions. A multichannel FPGA-based measurement system is implemented to process frequency signals without analog conditioning or ADC stages. Experimental validation was performed for CH4 (0–85%), CO2 (0–60%), H2, NH3, and H2S (1–20,000 ppm). The results demonstrate measurement uncertainty within 0.25–0.5%, with sensitivity reaching 350–748 Hz/ppm for H2, 455–750 Hz/ppm for NH3, and 253–375 Hz/ppm for H2S, while methane and carbon dioxide sensitivities reach up to 112 kHz/% and 98.7 kHz/%, respectively. Spectral analysis in the LTE-1800 band confirms improved noise immunity (up to 4.5×) and extended transmission capabilities. A 12-channel FPGA-based monitoring system (RDM-BP-1) with a 1 s sampling interval, IP67 protection, and wireless connectivity is developed and validated. The proposed architecture eliminates analog signal conditioning, reduces hardware complexity, and provides an easily expandable and reliable sensing solution for smart buildings, renewable energy systems, and cloud-integrated energy infrastructures.

ElectronicsVol. 15(9)
Vinnytsia National Technical University (UA), Poznań University of Technology (PL)
Industry, innovation and infrastructure
Openalex Percentile: Top 13%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.