Nano-Power OTA-Based Low-Pass Filter for Ultra-Low-Energy Biomedical Signal Processing

This paper presents a nanowatt-scale operational transconductance amplifier (OTA) and an electronically tunable third-order low-pass filter (LPF) designed for energy-constrained biomedical signal conditioning. The circuits are implemented in a 65 nm CMOS process and verified through comprehensive schematic-level simulations. Biased in the deep subthreshold region at 1 nA, the OTA achieves a 50 dB low-frequency gain, a 225 Hz unity-gain bandwidth at 10 pF load capacitance and an input-referred noise floor of 1.55 μV/√Hz, with a total power consumption of only 1.75 nW. The integrated third-order LPF provides a wide tuning range (37–668 Hz) via bias current modulation, exhibiting excellent linearity with a THD of 0.059% and a 65.3 dB dynamic range. Monte Carlo and PVT corner analyses demonstrate the design’s theoretical robustness against process variations and environmental fluctuations. ECG signal simulations validate the circuit’s effectiveness in suppressing high-frequency artifacts while preserving morphological integrity, providing a proof-of-concept for ultra-low-power wearable healthcare architectures.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-22
DOI
https://doi.org/10.3390/s26092586
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nano-Power OTA-Based Low-Pass Filter for Ultra-Low-Energy Biomedical Signal Processing

Tomasz Kulej, Fabian Khateb, Montree Kumngern
Sensors
Analog and Mixed-Signal Circuit Design
article

Nano-Power OTA-Based Low-Pass Filter for Ultra-Low-Energy Biomedical Signal Processing

Tomasz Kulej, Fabian Khateb, Montree Kumngern
article en

Abstract

This paper presents a nanowatt-scale operational transconductance amplifier (OTA) and an electronically tunable third-order low-pass filter (LPF) designed for energy-constrained biomedical signal conditioning. The circuits are implemented in a 65 nm CMOS process and verified through comprehensive schematic-level simulations. Biased in the deep subthreshold region at 1 nA, the OTA achieves a 50 dB low-frequency gain, a 225 Hz unity-gain bandwidth at 10 pF load capacitance and an input-referred noise floor of 1.55 μV/√Hz, with a total power consumption of only 1.75 nW. The integrated third-order LPF provides a wide tuning range (37–668 Hz) via bias current modulation, exhibiting excellent linearity with a THD of 0.059% and a 65.3 dB dynamic range. Monte Carlo and PVT corner analyses demonstrate the design’s theoretical robustness against process variations and environmental fluctuations. ECG signal simulations validate the circuit’s effectiveness in suppressing high-frequency artifacts while preserving morphological integrity, providing a proof-of-concept for ultra-low-power wearable healthcare architectures.

SensorsVol. 26(9)
Częstochowa University of Technology (PL), Brno University of Technology (CZ), King Mongkut's Institute of Technology Ladkrabang (TH), University of Defence (CZ)
Univerzita Obrany
Affordable and clean energy
Openalex Percentile: Top 11%
Analog and Mixed-Signal Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.