Direct Ink Writing–Based Fabrication and Evaluation of Customized High-Density Surface Electromyography Electrode Arrays for Hand Gesture Classification

High-density surface electromyography (HD-sEMG) is increasingly important for wearable hand-gesture recognition and human–machine interface (HMI) applications. However, commercial wet electrodes still require conductive creams and adhesive foams, which can cause impedance instability, skin irritation, and hygiene issues during long-term use, limiting wearable practicality. Here, we developed a gel-free 36-channel stretchable HD-sEMG electrode using a Direct Ink Writing (DIW) process and validated its printing precision, electrical/mechanical stability, and machine-learning-based gesture classification performance. Ag interconnects and dome-shaped Ag/AgCl electrodes were printed on a TPU substrate and encapsulated with PDMS. Process optimization achieved a line width of 217 ± 9.01 µm and a dome height of 569.3 ± 19.9 µm at a 4 mm pitch, close to the target dimensions. Based on area-normalized impedance (|Z|·A), the printed electrode showed lower impedance than a commercial electrode across the measured frequency range. During a 6-hour wear test, repeated EIS measurements showed that the 1 kHz impedance stabilized from 1.66 MΩ to 0.95–1.02 MΩ, while the coefficient of variation remained around 1% at most time points. Under 30% strain for 1000 tensile cycles, the electrode maintained electrical continuity and mechanical stability. In forearm HD-sEMG experiments, the electrode achieved SNRs of 17.06–21.34 dB (30% MVC) and 26.07–26.26 dB (100% MVC), and CNN and CNN–ViT models classified eight hand gestures with accuracies of 91.1% and 92.2%, respectively. These results demonstrate that the DIW-based gel-free electrodes can reliably acquire multi-channel muscle signals and suggest that muscle-informed channel grouping can be utilized in machine-learning frameworks for gesture applications.

Authors

Publication Details

Journal
Journal of Flexible and Printed Electronics
Published
2026-04-22
DOI
https://doi.org/10.56767/jfpe.250025
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Ink Writing–Based Fabrication and Evaluation of Customized High-Density Surface Electromyography Electrode Arrays for Hand Gesture Classification

Junghun Sung, Woongki Hong, Hongki Kang, Taeha Kim et al.
Journal of Flexible and Printed Electronics
Advanced Sensor and Energy Harvesting Materials
article

Direct Ink Writing–Based Fabrication and Evaluation of Customized High-Density Surface Electromyography Electrode Arrays for Hand Gesture Classification

Junghun Sung, Woongki Hong, Hongki Kang, Taeha Kim, Ui-In Lee, Hyeju Roh
article en

Abstract

High-density surface electromyography (HD-sEMG) is increasingly important for wearable hand-gesture recognition and human–machine interface (HMI) applications. However, commercial wet electrodes still require conductive creams and adhesive foams, which can cause impedance instability, skin irritation, and hygiene issues during long-term use, limiting wearable practicality. Here, we developed a gel-free 36-channel stretchable HD-sEMG electrode using a Direct Ink Writing (DIW) process and validated its printing precision, electrical/mechanical stability, and machine-learning-based gesture classification performance. Ag interconnects and dome-shaped Ag/AgCl electrodes were printed on a TPU substrate and encapsulated with PDMS. Process optimization achieved a line width of 217 ± 9.01 µm and a dome height of 569.3 ± 19.9 µm at a 4 mm pitch, close to the target dimensions. Based on area-normalized impedance (|Z|·A), the printed electrode showed lower impedance than a commercial electrode across the measured frequency range. During a 6-hour wear test, repeated EIS measurements showed that the 1 kHz impedance stabilized from 1.66 MΩ to 0.95–1.02 MΩ, while the coefficient of variation remained around 1% at most time points. Under 30% strain for 1000 tensile cycles, the electrode maintained electrical continuity and mechanical stability. In forearm HD-sEMG experiments, the electrode achieved SNRs of 17.06–21.34 dB (30% MVC) and 26.07–26.26 dB (100% MVC), and CNN and CNN–ViT models classified eight hand gestures with accuracies of 91.1% and 92.2%, respectively. These results demonstrate that the DIW-based gel-free electrodes can reliably acquire multi-channel muscle signals and suggest that muscle-informed channel grouping can be utilized in machine-learning frameworks for gesture applications.

Journal of Flexible and Printed Electronics
Quality Education
Openalex Percentile: Top 9%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.