Dependence of Magnetic Resonance Elastography‐Derived Stiffness Values on Selected Imaging Parameters

PURPOSE: To evaluate the influence of driver power and slice thickness on magnetic resonance elastography (MRE)-derived liver stiffness in human subjects and a tissue-mimicking phantom. METHODS: A prospective single-center observational study was performed involving 34 adult participants (20 males; median age: 29.0 ± 29.3 years) and a standard phantom. MRE was conducted on a 1.5T scanner using a 2D gradient-recalled echo-based sequence. Human data were acquired at driver powers of 25%-100% and slice thicknesses of 5 and 10 mm. The phantom was scanned with driver powers of 10%-100% and slice thicknesses from 2 to 10 mm. Two region-of-interest (ROI) approaches were applied: (A) fixed-location ROIs and (B) largest measurable ROIs. Stiffness maps were generated using the MMDI inversion algorithm. Statistical analysis included repeated measures ANOVA, paired t-tests or Wilcoxon signed-rank tests, and intraclass correlation coefficients (ICCs). RESULTS: Measured whole-liver stiffness varied modestly over the driver power range, with the effect reaching statistical significance in Method B analysis (p = 0.037). Measurements of individual slices varied more significantly with driver power (Method A: p = 0.031; Method B: p < 0.001). Slice thickness had a significant effect on individual slice measurements (Method B: p = 0.007) but not on whole-liver measurements. In phantom studies, both parameters significantly influenced stiffness (p < 0.001 to p = 0.017). ICCs indicated good to excellent repeatability in vivo (0.79-0.96) and moderate to good repeatability in the phantom (0.62-0.89). CONCLUSION: The results demonstrate that measured MRE-derived liver stiffness can be influenced by driver power and slice thickness, underscoring the need for standardization of these parameters in both clinical practice and research.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-04-22
DOI
https://doi.org/10.1002/mrm.70391
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dependence of Magnetic Resonance Elastography‐Derived Stiffness Values on Selected Imaging Parameters

Vitaliy Atamaniuk, Łukasz Hańczyk, Marian Cholewa, Marzanna Obrzut
Magnetic Resonance in Medicine
Ultrasound Imaging and Elastography
article

Dependence of Magnetic Resonance Elastography‐Derived Stiffness Values on Selected Imaging Parameters

Vitaliy Atamaniuk, Łukasz Hańczyk, Marian Cholewa, Marzanna Obrzut
article en

Abstract

PURPOSE: To evaluate the influence of driver power and slice thickness on magnetic resonance elastography (MRE)-derived liver stiffness in human subjects and a tissue-mimicking phantom. METHODS: A prospective single-center observational study was performed involving 34 adult participants (20 males; median age: 29.0 ± 29.3 years) and a standard phantom. MRE was conducted on a 1.5T scanner using a 2D gradient-recalled echo-based sequence. Human data were acquired at driver powers of 25%-100% and slice thicknesses of 5 and 10 mm. The phantom was scanned with driver powers of 10%-100% and slice thicknesses from 2 to 10 mm. Two region-of-interest (ROI) approaches were applied: (A) fixed-location ROIs and (B) largest measurable ROIs. Stiffness maps were generated using the MMDI inversion algorithm. Statistical analysis included repeated measures ANOVA, paired t-tests or Wilcoxon signed-rank tests, and intraclass correlation coefficients (ICCs). RESULTS: Measured whole-liver stiffness varied modestly over the driver power range, with the effect reaching statistical significance in Method B analysis (p = 0.037). Measurements of individual slices varied more significantly with driver power (Method A: p = 0.031; Method B: p < 0.001). Slice thickness had a significant effect on individual slice measurements (Method B: p = 0.007) but not on whole-liver measurements. In phantom studies, both parameters significantly influenced stiffness (p < 0.001 to p = 0.017). ICCs indicated good to excellent repeatability in vivo (0.79-0.96) and moderate to good repeatability in the phantom (0.62-0.89). CONCLUSION: The results demonstrate that measured MRE-derived liver stiffness can be influenced by driver power and slice thickness, underscoring the need for standardization of these parameters in both clinical practice and research.

Magnetic Resonance in Medicine
Rzeszów University of Technology (PL), University of Rzeszów (PL)
Uniwersytet Rzeszowski, Narodowa Agencja Wymiany Akademickiej
Openalex Percentile: Top 13%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.