Vascular ultrasound in patients with mechanical circulatory support devices: from pre-implant assessment to post-decannulation surveillance

Mechanical circulatory support (MCS) devices, including extracorporeal membrane oxygenation (ECMO), left ventricular assist devices (LVADs), and intra-aortic balloon pumps (IABP), are increasingly used in patients with severe cardiac or cardiorespiratory failure. Despite major technical advances, vascular complications related to cannulation, device support, and decannulation remain frequent. Duplex ultrasound (DUS) is the primary vascular imaging modality because it is fast, can be performed at the patient’s bedside, is repeatable, and provides functional data via Doppler imaging. However, this is a specialized examination requiring expertise, as the flows are significantly altered by MCS, and the ultrasound findings are specific. This review summarizes current applications of DUS in patients supported with extracardiac MCS devices, organized into three key phases: pre-implant assessment, monitoring during mechanical support, and post-decannulation surveillance. Pre-implant DUS allows detailed evaluation of arterial and venous anatomy, vessel diameter, patency, and wall morphology, guiding cannulation strategy and cannula selection while facilitating ultrasound-guided percutaneous access. During MCS support, DUS plays a critical role in assessing limb perfusion, cannula positioning, and diagnosing vascular complications, particularly in patients unable to report ischemic symptoms. After decannulation, systematic ultrasound surveillance enables early detection of access-related complications, including thrombosis, pseudoaneurysm, arteriovenous fistula, arterial dissection, and acute limb ischemia. The objective is to guide the ultrasound practitioner in performing and interpreting DUS at each stage of the assessment of critically ill patients with an MCS device.

Authors

Institutions

Publication Details

Journal
Critical Care
Published
2026-04-22
DOI
https://doi.org/10.1186/s13054-026-06026-5
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vascular ultrasound in patients with mechanical circulatory support devices: from pre-implant assessment to post-decannulation surveillance

Bernard Cholley, Arianna Magna, Guillaume Goudot, Hélène Nougue
Critical Care
Mechanical Circulatory Support Devices
article

Vascular ultrasound in patients with mechanical circulatory support devices: from pre-implant assessment to post-decannulation surveillance

Bernard Cholley, Arianna Magna, Guillaume Goudot, Hélène Nougue
article en

Abstract

Mechanical circulatory support (MCS) devices, including extracorporeal membrane oxygenation (ECMO), left ventricular assist devices (LVADs), and intra-aortic balloon pumps (IABP), are increasingly used in patients with severe cardiac or cardiorespiratory failure. Despite major technical advances, vascular complications related to cannulation, device support, and decannulation remain frequent. Duplex ultrasound (DUS) is the primary vascular imaging modality because it is fast, can be performed at the patient’s bedside, is repeatable, and provides functional data via Doppler imaging. However, this is a specialized examination requiring expertise, as the flows are significantly altered by MCS, and the ultrasound findings are specific. This review summarizes current applications of DUS in patients supported with extracardiac MCS devices, organized into three key phases: pre-implant assessment, monitoring during mechanical support, and post-decannulation surveillance. Pre-implant DUS allows detailed evaluation of arterial and venous anatomy, vessel diameter, patency, and wall morphology, guiding cannulation strategy and cannula selection while facilitating ultrasound-guided percutaneous access. During MCS support, DUS plays a critical role in assessing limb perfusion, cannula positioning, and diagnosing vascular complications, particularly in patients unable to report ischemic symptoms. After decannulation, systematic ultrasound surveillance enables early detection of access-related complications, including thrombosis, pseudoaneurysm, arteriovenous fistula, arterial dissection, and acute limb ischemia. The objective is to guide the ultrasound practitioner in performing and interpreting DUS at each stage of the assessment of critically ill patients with an MCS device.

Critical Care
Université Paris Cité (FR), Assistance Publique – Hôpitaux de Paris (FR), Hôpital Européen Georges-Pompidou (FR)
Openalex Percentile: Top 17%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.