Small disturbance oscillation suppression strategy for doubly-fed wind turbine based on joint control of LADRC and AQPR

To address the issue that small-signal oscillations on the rotor side of doubly fed wind turbines may propagate through multiple transmission paths and induce subsynchronous oscillations, this paper proposes a small-signal oscillation suppression strategy based on the combined control of linear active disturbance rejection control (LADRC) and adaptive quasi-proportional resonant (AQPR) control. LADRC is employed to replace the conventional PI controller in the inner current loop of the rotor-side converter, where real-time disturbance estimation and compensation effectively block the propagation of small-signal oscillations within the current loop. Meanwhile, by integrating the intrinsic time-scale decomposition (ITD)-based oscillation frequency identification algorithm with a frequency-locking update module, an AQPR suppressor is constructed to achieve frequency-selective suppression of time-varying small-signal oscillations embedded in cross-coupled current signals. Based on this framework, an LADRC–AQPR combined current-loop control system is established, and key parameters are optimally designed to mitigate subsynchronous control interactions. Simulation and experimental results further provide systematic comparisons between LADRC-, QPR-, and ITD-based methods and their conventional counterparts in terms of oscillation identification and suppression performance, demonstrating that the proposed method exhibits superior dynamic response and enhanced robustness. Moreover, comparative validations under three typical operating conditions confirm that the proposed combined control strategy significantly outperforms conventional approaches in suppressing small-signal oscillations and can effectively mitigate time-varying small-signal oscillations in grid-connected doubly fed wind turbine systems.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-22
DOI
https://doi.org/10.1038/s41598-026-49356-8
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Small disturbance oscillation suppression strategy for doubly-fed wind turbine based on joint control of LADRC and AQPR

Renjie Liu, Chenchen Li, Shuyu Zhang, Chenglong Huang et al.
Scientific Reports
Wind Turbine Control Systems
article

Small disturbance oscillation suppression strategy for doubly-fed wind turbine based on joint control of LADRC and AQPR

Renjie Liu, Chenchen Li, Shuyu Zhang, Chenglong Huang, Jiale Zhang, Songcai Zhang, Chunhui Liang
article en

Abstract

To address the issue that small-signal oscillations on the rotor side of doubly fed wind turbines may propagate through multiple transmission paths and induce subsynchronous oscillations, this paper proposes a small-signal oscillation suppression strategy based on the combined control of linear active disturbance rejection control (LADRC) and adaptive quasi-proportional resonant (AQPR) control. LADRC is employed to replace the conventional PI controller in the inner current loop of the rotor-side converter, where real-time disturbance estimation and compensation effectively block the propagation of small-signal oscillations within the current loop. Meanwhile, by integrating the intrinsic time-scale decomposition (ITD)-based oscillation frequency identification algorithm with a frequency-locking update module, an AQPR suppressor is constructed to achieve frequency-selective suppression of time-varying small-signal oscillations embedded in cross-coupled current signals. Based on this framework, an LADRC–AQPR combined current-loop control system is established, and key parameters are optimally designed to mitigate subsynchronous control interactions. Simulation and experimental results further provide systematic comparisons between LADRC-, QPR-, and ITD-based methods and their conventional counterparts in terms of oscillation identification and suppression performance, demonstrating that the proposed method exhibits superior dynamic response and enhanced robustness. Moreover, comparative validations under three typical operating conditions confirm that the proposed combined control strategy significantly outperforms conventional approaches in suppressing small-signal oscillations and can effectively mitigate time-varying small-signal oscillations in grid-connected doubly fed wind turbine systems.

Scientific Reports
Changchun Institute of Technology (CN), Switch (CH)
Department of Science and Technology of Jilin Province, Jilin Scientific and Technological Development Program
Affordable and clean energy
Openalex Percentile: Top 9%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.