Stator inter-turn short-circuit detection in doubly-fed induction generators using rotor current analysis
Early detection of inter-turn short-circuit faults in the stator windings of Doubly-Fed Induction Generators (DFIGs) is essential to ensure proper maintenance planning and avoid critical failures. This paper presents a technique to detect and quantify this type of fault to assess its severity. The proposed approach consists of analyzing the rotor currents of DFIGs in Park reference frame. A theoretical study is carried out, accompanied by experimental validation using a test bench and a data acquisition (DAQ) system. This study reveals a new fault indicator based on analysis of geometric shape of rotor currents. Quantifying the evolution of this indicator enables the estimation of defect severity with a relative error of 2%. Qualitative and quantitative analysis of it facilitates the maintenance supervisor’s decision-making process. The results demonstrate the potential of this approach, which is characterized by its simplicity, reliability and effectiveness.
Authors
- Nicolas Héraud (ORCID: https://orcid.org/0000-0002-1917-943X)
- Eric Jean Roy Sambatra
- Nomentsoa Michel Raphael Rakotoarivelo (ORCID: https://orcid.org/0009-0000-2131-0487)
Institutions
- Université de Corse Pascal Paoli (FR)
- Université d’Antsiranana (MG)
Publication Details
- Journal
- Wind Engineering
- Published
- 2026-04-21
- DOI
- https://doi.org/10.1177/0309524x261443816
- Primary Topic
- Machine Fault Diagnosis Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00