Effects of Prolonged Cryogenic Exposure on the Electrical Degradation of Stator Main Insulation in Wind Turbines

Epoxy-glass-mica composite materials are widely used as electrical insulating materials in high-voltage rotating machinery due to their layered structure and excellent dielectric properties. Taking the F-class epoxy glass with a small amount of rubber powder mica tape commonly used as the main insulation of wind turbine stator coils as the research object, 7-day, 14-day, 21-day, and 28-day low-temperature treatment tests were conducted at −50 °C. The surface morphology and chemical structure changes of the materials were characterized by SEM and FTIR, and the influence laws of low-temperature treatment on the electrical properties of the mica tape insulation materials were systematically studied. The experimental results show that the low-temperature environment will induce microcracks and interface delamination and other structural damages, but no obvious change in the chemical structure of the mica tape was observed. With the extension of the low-temperature treatment time, the electrical properties of the mica tape show a deteriorating trend, and after 28 days of low-temperature treatment, the breakdown field strength of the F-class mica tape decreased by approximately 18.5%, and the volume conductivity overall increased by about two orders of magnitude. This indicates that the microcrack defects induced by low-temperature will lead to an enhanced electrical-thermal coupling effect in the insulation structure, thereby accelerating the degradation process of the insulation material. This reveals the degradation mechanism of wind turbine stator main insulation from “structural damage” to “performance degradation” and then to “insulation aging” under low-temperature conditions, providing a theoretical basis for the design and reliability assessment of insulation systems in wind turbine generators in cold regions.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-04-22
DOI
https://doi.org/10.3390/ma19091675
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Prolonged Cryogenic Exposure on the Electrical Degradation of Stator Main Insulation in Wind Turbines

Haitao Hu, Zheng Dong, Mingpeng He, Yanli Liu et al.
Materials
High voltage insulation and dielectric phenomena
article

Effects of Prolonged Cryogenic Exposure on the Electrical Degradation of Stator Main Insulation in Wind Turbines

Haitao Hu, Zheng Dong, Mingpeng He, Yanli Liu, Zhongyi Huang, Junguo Gao
article en

Abstract

Epoxy-glass-mica composite materials are widely used as electrical insulating materials in high-voltage rotating machinery due to their layered structure and excellent dielectric properties. Taking the F-class epoxy glass with a small amount of rubber powder mica tape commonly used as the main insulation of wind turbine stator coils as the research object, 7-day, 14-day, 21-day, and 28-day low-temperature treatment tests were conducted at −50 °C. The surface morphology and chemical structure changes of the materials were characterized by SEM and FTIR, and the influence laws of low-temperature treatment on the electrical properties of the mica tape insulation materials were systematically studied. The experimental results show that the low-temperature environment will induce microcracks and interface delamination and other structural damages, but no obvious change in the chemical structure of the mica tape was observed. With the extension of the low-temperature treatment time, the electrical properties of the mica tape show a deteriorating trend, and after 28 days of low-temperature treatment, the breakdown field strength of the F-class mica tape decreased by approximately 18.5%, and the volume conductivity overall increased by about two orders of magnitude. This indicates that the microcrack defects induced by low-temperature will lead to an enhanced electrical-thermal coupling effect in the insulation structure, thereby accelerating the degradation process of the insulation material. This reveals the degradation mechanism of wind turbine stator main insulation from “structural damage” to “performance degradation” and then to “insulation aging” under low-temperature conditions, providing a theoretical basis for the design and reliability assessment of insulation systems in wind turbine generators in cold regions.

MaterialsVol. 19(9)
Harbin University of Science and Technology (CN), Dongfang Electric Corporation (China) (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 13%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.