Controlling electrode fouling in pulsed electric field (PEF)-based disinfection of spoiled E-coating paints

Abstract The present study investigated the feasibility of applying pulsed electric field (PEF) treatment in anodic electrodeposition (AED) paints without inducing undesired paint deposition on electrode surfaces. PEF treatment is a promising non-thermal technique for microbial inactivation and control in E-coating lines. However, paint deposition on treatment electrodes can cause operational limitations. This study investigates paint stability, coating performance, and electrodeposition mechanisms during PEF treatment of industrial AED emulsions. Using both unipolar and bipolar square-wave pulses at varying durations and charge symmetry, deposition behavior and paint quality were evaluated under continuous flow for PEF treatments known to induce at least a 99% bacterial inactivation on bacteria isolated from E-coating lines. Intensive and repeated PEF treatment of AED paint did not impair the quality of the subsequent coating and did not change the properties of the paint. Paint quality remained unaffected across all trials. Regarding the coagulation and paint deposition on the PEF treatment electrodes, results show that unipolar pulses induce paint coagulation at the anode, even at short durations (when pulses are in the range of the double layer threshold time ≥ 1 µs). In contrast, bipolar pulses with nominal pulse durations ≤ 1.5 µs (0.75 + 0.75 µs) prevented electrode fouling and allowed uninterrupted treatment for over 10 h, without electrode fouling. Furthermore, the application of charge-symmetrical bipolar (CS-bipolar) pulses eliminated deposition entirely, even at nominal durations up to 2.9 µs (1.48 + 1.41 µs). Findings demonstrate that pulse polarity, charge balance, and field symmetry are critical for deposition-free PEF operation in AED systems. These insights provide a technical foundation for scaling PEF in industrial paint processing.

Authors

Institutions

Publication Details

Journal
Journal of Coatings Technology and Research
Published
2026-04-22
DOI
https://doi.org/10.1007/s11998-026-01304-x
Primary Topic
Electrokinetic Soil Remediation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Controlling electrode fouling in pulsed electric field (PEF)-based disinfection of spoiled E-coating paints

Christian Gusbeth, Wolfgang Frey, Georg Müller
Journal of Coatings Technology and Research
Electrokinetic Soil Remediation Techniques
article

Controlling electrode fouling in pulsed electric field (PEF)-based disinfection of spoiled E-coating paints

Christian Gusbeth, Wolfgang Frey, Georg Müller
article en

Abstract

Abstract The present study investigated the feasibility of applying pulsed electric field (PEF) treatment in anodic electrodeposition (AED) paints without inducing undesired paint deposition on electrode surfaces. PEF treatment is a promising non-thermal technique for microbial inactivation and control in E-coating lines. However, paint deposition on treatment electrodes can cause operational limitations. This study investigates paint stability, coating performance, and electrodeposition mechanisms during PEF treatment of industrial AED emulsions. Using both unipolar and bipolar square-wave pulses at varying durations and charge symmetry, deposition behavior and paint quality were evaluated under continuous flow for PEF treatments known to induce at least a 99% bacterial inactivation on bacteria isolated from E-coating lines. Intensive and repeated PEF treatment of AED paint did not impair the quality of the subsequent coating and did not change the properties of the paint. Paint quality remained unaffected across all trials. Regarding the coagulation and paint deposition on the PEF treatment electrodes, results show that unipolar pulses induce paint coagulation at the anode, even at short durations (when pulses are in the range of the double layer threshold time ≥ 1 µs). In contrast, bipolar pulses with nominal pulse durations ≤ 1.5 µs (0.75 + 0.75 µs) prevented electrode fouling and allowed uninterrupted treatment for over 10 h, without electrode fouling. Furthermore, the application of charge-symmetrical bipolar (CS-bipolar) pulses eliminated deposition entirely, even at nominal durations up to 2.9 µs (1.48 + 1.41 µs). Findings demonstrate that pulse polarity, charge balance, and field symmetry are critical for deposition-free PEF operation in AED systems. These insights provide a technical foundation for scaling PEF in industrial paint processing.

Journal of Coatings Technology and Research
Karlsruhe Institute of Technology (DE)
Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie
Openalex Percentile: Top 9%
Electrokinetic Soil Remediation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.