Radiological assessment of navigated pedicle screw placement in the cervical spine: a comparative evaluation of a novel orthogonal view evaluation method (ovem) versus other classification systems (Neo/Modified Gertzbein-Robbins/Wiesner)

STUDY DESIGN: A retrospective, comparison study. PURPOSE: This study compares different computed tomography (CT)-based methods for evaluating the postoperative position of cervical pedicle screws (CPS). Specifically, our novel Orthogonal View Evaluation Method (OVEM) alongside the Neo, modified Gerzbein-Robbins, and Wiesner classifications to validate a standardized system for postoperative assessment of screw placement in the cervical spine. METHODS: All enrolled patients underwent navigated, posterior stabilization using CPS in the subaxial spine (C3-C6). The intra- and inter-observer assessment was carried out using two statistical methods: the Fleiss Kappa and the Gwet´s agreement coefficient (Gwet´s AC1). RESULTS: A total of 90 (60 men and 30 women) patients with total number of screws 275 (median 2, IQR 2 to 4) were enrolled in the study. The OVEM classification demonstrated a statistically significant lower number of screws categorized as correctly placed compared to the other classification across all reviewers (p < 0.001). The reliability analysis showed the highest agreement for OVEM 2 and Neo 2 for Reviewer 1, with Gwet's AC1 (95% CI) of 0.83 (0.77, 0.888) and OVEM for Reviewers 2 and 3 with Gwet's AC1 (95% CI) of 0.87 (0.818, 0.917). Intra-observer agreement was highest for Reviewer 1 in OVEM 2 with Gwet's AC1 (95% CI) of 0.97 (0.943, 1.0), for Reviewer 2 in Neo with 0.97 (0.941, 1.0), and for Reviewer 3 in OVEM with 0.90 (0.829, 0.970). Inter-observer agreement was highest for Neo, with Gwet's AC1 (95% CI) of 0.89 (0.855, 0.927) among Reviewers 1, 2, and 3. CONCLUSIONS: OVEM evaluation method appears to be more sensitive to detect misplaced screws, has similar reliability and reproducibility in comparison to Neo/modified Gerzbein-Robbins/Wiesner classifications.

Authors

Institutions

Publication Details

Journal
European Spine Journal
Published
2026-11-17
DOI
https://doi.org/10.1007/s00586-026-10463-9
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Radiological assessment of navigated pedicle screw placement in the cervical spine: a comparative evaluation of a novel orthogonal view evaluation method (ovem) versus other classification systems (Neo/Modified Gertzbein-Robbins/Wiesner)

Lars‐Owe Koskinen, Lukas Bobinski, Johan Wänman, Duff John Michael Duff et al.
1 links
European Spine Journal
Spinal Fractures and Fixation Techniques
article

Radiological assessment of navigated pedicle screw placement in the cervical spine: a comparative evaluation of a novel orthogonal view evaluation method (ovem) versus other classification systems (Neo/Modified Gertzbein-Robbins/Wiesner)

Lars‐Owe Koskinen, Lukas Bobinski, Johan Wänman, Duff John Michael Duff, Hassib Lewall, Anders Berglund, Joel Axelsson
article en

Abstract

STUDY DESIGN: A retrospective, comparison study. PURPOSE: This study compares different computed tomography (CT)-based methods for evaluating the postoperative position of cervical pedicle screws (CPS). Specifically, our novel Orthogonal View Evaluation Method (OVEM) alongside the Neo, modified Gerzbein-Robbins, and Wiesner classifications to validate a standardized system for postoperative assessment of screw placement in the cervical spine. METHODS: All enrolled patients underwent navigated, posterior stabilization using CPS in the subaxial spine (C3-C6). The intra- and inter-observer assessment was carried out using two statistical methods: the Fleiss Kappa and the Gwet´s agreement coefficient (Gwet´s AC1). RESULTS: A total of 90 (60 men and 30 women) patients with total number of screws 275 (median 2, IQR 2 to 4) were enrolled in the study. The OVEM classification demonstrated a statistically significant lower number of screws categorized as correctly placed compared to the other classification across all reviewers (p < 0.001). The reliability analysis showed the highest agreement for OVEM 2 and Neo 2 for Reviewer 1, with Gwet's AC1 (95% CI) of 0.83 (0.77, 0.888) and OVEM for Reviewers 2 and 3 with Gwet's AC1 (95% CI) of 0.87 (0.818, 0.917). Intra-observer agreement was highest for Reviewer 1 in OVEM 2 with Gwet's AC1 (95% CI) of 0.97 (0.943, 1.0), for Reviewer 2 in Neo with 0.97 (0.941, 1.0), and for Reviewer 3 in OVEM with 0.90 (0.829, 0.970). Inter-observer agreement was highest for Neo, with Gwet's AC1 (95% CI) of 0.89 (0.855, 0.927) among Reviewers 1, 2, and 3. CONCLUSIONS: OVEM evaluation method appears to be more sensitive to detect misplaced screws, has similar reliability and reproducibility in comparison to Neo/modified Gerzbein-Robbins/Wiesner classifications.

European Spine Journal
Statistics Sweden (SE), University Hospital of Umeå (SE), Mediclinic City Hospital (AE), Statisticon (Sweden) (SE), Umeå University (SE)
Good health and well-being
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon