Detection of Particulate Matter With Lock‐In Thermography

ABSTRACT Ultrafine particles (UFPs), particularly black carbon (BC), are major contributors to air pollution, climate change, and health risks. Conventional quantification techniques such as Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Raman Spectroscopy, while effective, suffer from limitations in real‐time analysis, sample representativeness, and scalability. Lock‐in thermography (LIT) has emerged as a promising alternative, offering enhanced sensitivity and real‐time monitoring for nanoparticle detection. In this study, we employ LIT to quantify black carbon. Two measurement configurations—transmission and reflection mode—are utilized to assess spatial distribution and concentration dependence of BC particles collected on filter substrates. Our results demonstrate a strong correlation between measured thermal signals and reference concentrations, confirming LIT's precision in quantifying BC with high reproducibility. The imaging capability further reveals non‐homogeneous particle deposition patterns, which would be challenging to capture using conventional point‐based techniques. These findings establish LIT as a viable tool for real‐time BC quantification in environmental monitoring and industrial applications, overcoming the constraints of traditional measurement approaches.

Authors

Institutions

Publication Details

Journal
CleanMat.
Published
2026-04-22
DOI
https://doi.org/10.1002/clem.70030
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Particulate Matter With Lock‐In Thermography

Daniel Fehr, Christoph Geers, Mathias Bonmarin, Gunter Festel et al.
CleanMat.
Thermography and Photoacoustic Techniques
article

Detection of Particulate Matter With Lock‐In Thermography

Daniel Fehr, Christoph Geers, Mathias Bonmarin, Gunter Festel, Alina Oetsen, Andreas Traube
article en

Abstract

ABSTRACT Ultrafine particles (UFPs), particularly black carbon (BC), are major contributors to air pollution, climate change, and health risks. Conventional quantification techniques such as Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Raman Spectroscopy, while effective, suffer from limitations in real‐time analysis, sample representativeness, and scalability. Lock‐in thermography (LIT) has emerged as a promising alternative, offering enhanced sensitivity and real‐time monitoring for nanoparticle detection. In this study, we employ LIT to quantify black carbon. Two measurement configurations—transmission and reflection mode—are utilized to assess spatial distribution and concentration dependence of BC particles collected on filter substrates. Our results demonstrate a strong correlation between measured thermal signals and reference concentrations, confirming LIT's precision in quantifying BC with high reproducibility. The imaging capability further reveals non‐homogeneous particle deposition patterns, which would be challenging to capture using conventional point‐based techniques. These findings establish LIT as a viable tool for real‐time BC quantification in environmental monitoring and industrial applications, overcoming the constraints of traditional measurement approaches.

CleanMat.
University of Fribourg (CH), ZHAW Zurich University of Applied Sciences (CH)
Climate action
Openalex Percentile: Top 9%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.