Low-cost point-of-care wireless multimodal wearable to monitor vitals and tissue oxygen saturation

Abstract For centuries, infectious diseases have represented a leading cause of global morbidity and mortality, with high transmissibility posing persistent public health challenges. Because early physiological changes often precede overt clinical symptoms, continuous physiological monitoring may provide opportunities for earlier recognition of illness and timely intervention. In this study, we developed and evaluated a wireless wearable device capable of measuring microvascular tissue oxygen saturation, respiratory rate, respiratory rhythm, breathing depth, heart rate, and pulse strength. Device performance was assessed in a clinical study involving healthy participants performing breath-holding, paced breathing, and mild hypercapnia tasks. Breathing rate and heart rate derived from the wearable device were compared with corresponding measurements obtained from commercial physiological monitoring systems. Chest tissue oxygen saturation measured by the wearable device was additionally evaluated alongside peripheral blood oxygen saturation measured using a commercial pulse oximeter. Across all tasks, wearable-derived breathing rate and heart rate demonstrated strong agreement with commercial systems, with small biases (⩽0.19 breaths/min for breathing rate and ⩽0.47 beats/min for heart rate). Chest tissue oxygen saturation exhibited distinct and rapid responses during breath-holding and mild hypercapnia, whereas peripheral oxygen saturation showed delayed or inconsistent changes. During breath-holding, changes in tissue oxygenation preceded peripheral desaturation by approximately 10 s. Collectively, these findings demonstrate the feasibility of the wearable device for real-time, continuous monitoring of cardiorespiratory parameters and microvascular tissue oxygenation, and suggest that tissue-level oxygenation measurements may provide complementary physiological information relevant to early respiratory stress in both general health and infectious disease research contexts.

Authors

Institutions

Publication Details

Journal
Journal of Physics Photonics
Published
2026-04-22
DOI
https://doi.org/10.1088/2515-7647/ae637f
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-cost point-of-care wireless multimodal wearable to monitor vitals and tissue oxygen saturation

Amir Gandjbakhche, Kosar Khaksari, Babak Shadgan, Soongho Park et al.
Journal of Physics Photonics
Non-Invasive Vital Sign Monitoring
article

Low-cost point-of-care wireless multimodal wearable to monitor vitals and tissue oxygen saturation

Amir Gandjbakhche, Kosar Khaksari, Babak Shadgan, Soongho Park, Vinay Veluvolu, Thien Nguyen, Abigail Frankenberg, Jinho Park, William S Martin, Tanya Azar, Tony George
article en

Abstract

Abstract For centuries, infectious diseases have represented a leading cause of global morbidity and mortality, with high transmissibility posing persistent public health challenges. Because early physiological changes often precede overt clinical symptoms, continuous physiological monitoring may provide opportunities for earlier recognition of illness and timely intervention. In this study, we developed and evaluated a wireless wearable device capable of measuring microvascular tissue oxygen saturation, respiratory rate, respiratory rhythm, breathing depth, heart rate, and pulse strength. Device performance was assessed in a clinical study involving healthy participants performing breath-holding, paced breathing, and mild hypercapnia tasks. Breathing rate and heart rate derived from the wearable device were compared with corresponding measurements obtained from commercial physiological monitoring systems. Chest tissue oxygen saturation measured by the wearable device was additionally evaluated alongside peripheral blood oxygen saturation measured using a commercial pulse oximeter. Across all tasks, wearable-derived breathing rate and heart rate demonstrated strong agreement with commercial systems, with small biases (⩽0.19 breaths/min for breathing rate and ⩽0.47 beats/min for heart rate). Chest tissue oxygen saturation exhibited distinct and rapid responses during breath-holding and mild hypercapnia, whereas peripheral oxygen saturation showed delayed or inconsistent changes. During breath-holding, changes in tissue oxygenation preceded peripheral desaturation by approximately 10 s. Collectively, these findings demonstrate the feasibility of the wearable device for real-time, continuous monitoring of cardiorespiratory parameters and microvascular tissue oxygenation, and suggest that tissue-level oxygenation measurements may provide complementary physiological information relevant to early respiratory stress in both general health and infectious disease research contexts.

Journal of Physics PhotonicsVol. 8(2)
University of British Columbia (CA), National Heart, Lung, and Blood Institute (US), Eunice Kennedy Shriver National Institute of Child Health and Human Development (US)
Good health and well-being
Openalex Percentile: Top 22%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.