Numerical and Experimental Assessment of Structural Performance and Axial Compression Capacity of Screw-Connected Built-Up Cold-Formed Steel Members

Recently, cold-formed steel (CFS) structural systems have been increasingly used in building applications due to their lightweight characteristics, ease of fabrication, and efficient construction processes. Among these systems, built-up CFS columns are widely adopted to enhance load-carrying capacity; however, their axial compression behavior and failure mechanisms have not yet been fully clarified. This study aims to investigate the axial compression performance of built-up cold-formed steel columns through a combined experimental and numerical approach. This study investigates the axial compression performance of built-up cold-formed steel columns using a combined experimental and numerical approach. Following the full-scale testing of five different configurations, finite element models were developed in ABAQUS using the obtained material properties. The experimental results were used to validate and calibrate the finite element models, which provided a detailed simulation of the nonlinear structural behavior of the columns. The experimental load–displacement responses were compared with the numerical results to evaluate the accuracy of the finite element models and to identify the axial load-carrying capacity and dominant failure modes of the built-up columns. Furthermore, the tensile pull-out behavior of 3.9 mm diameter self-drilling screws utilized in the built-up column connections was examined through expedient fastener tests to facilitate a more profound understanding of the load transfer mechanism. The results highlight the influence of built-up configuration and connection behavior on the axial compression performance of CFS columns, providing practical insights for improving the design and numerical modeling of screw-connected built-up cold-formed steel column systems.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-04-22
DOI
https://doi.org/10.3390/buildings16091651
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and Experimental Assessment of Structural Performance and Axial Compression Capacity of Screw-Connected Built-Up Cold-Formed Steel Members

Zeynep Fırat Alemdar, Nefya Soysal
Buildings
Structural Load-Bearing Analysis
article

Numerical and Experimental Assessment of Structural Performance and Axial Compression Capacity of Screw-Connected Built-Up Cold-Formed Steel Members

Zeynep Fırat Alemdar, Nefya Soysal
article en

Abstract

Recently, cold-formed steel (CFS) structural systems have been increasingly used in building applications due to their lightweight characteristics, ease of fabrication, and efficient construction processes. Among these systems, built-up CFS columns are widely adopted to enhance load-carrying capacity; however, their axial compression behavior and failure mechanisms have not yet been fully clarified. This study aims to investigate the axial compression performance of built-up cold-formed steel columns through a combined experimental and numerical approach. This study investigates the axial compression performance of built-up cold-formed steel columns using a combined experimental and numerical approach. Following the full-scale testing of five different configurations, finite element models were developed in ABAQUS using the obtained material properties. The experimental results were used to validate and calibrate the finite element models, which provided a detailed simulation of the nonlinear structural behavior of the columns. The experimental load–displacement responses were compared with the numerical results to evaluate the accuracy of the finite element models and to identify the axial load-carrying capacity and dominant failure modes of the built-up columns. Furthermore, the tensile pull-out behavior of 3.9 mm diameter self-drilling screws utilized in the built-up column connections was examined through expedient fastener tests to facilitate a more profound understanding of the load transfer mechanism. The results highlight the influence of built-up configuration and connection behavior on the axial compression performance of CFS columns, providing practical insights for improving the design and numerical modeling of screw-connected built-up cold-formed steel column systems.

BuildingsVol. 16(9)
Yıldız Technical University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, Yildiz Teknik Üniversitesi
Sustainable cities and communities
Openalex Percentile: Top 10%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.