Comparative evaluation of large language models for generating CAD-RADS 2.0-compliant diagnostic conclusions in cardiac CT reports

OBJECTIVES: Coronary computed tomography angiography (CCTA) has become a cornerstone in non-invasive CAD diagnosis and risk stratification. To standardize reporting and improve clinical decision-making, the CAD-RADS 2.0 system was introduced. This study evaluates the performance of four LLMs, GPT-4o, Gemini 2.0 Flash, DeepSeek V, and Copilot in generating CAD-RADS 2.0-compliant conclusions from standardized CCTA reports. MATERIALS AND METHODS: A total of 196 anonymized CCTA reports were retrospectively analyzed. Each LLM was prompted to provide CAD-RADS 2.0 classifications and follow-up recommendations. Ground truth labels were assigned by a senior radiologist. Performance metrics (accuracy, precision, recall, F1-score), execution times, and agreement (Cohen's kappa) with expert interpretation were computed. Interobserver agreement between junior and senior radiologists was also assessed. RESULTS: LLMs demonstrated good-to-excellent agreement with expert classifications: DeepSeek V (κ = 0.771), Copilot (κ = 0.761), GPT-4o (κ = 0.759), and Gemini 2.0 Flash (κ = 0.634). DeepSeek V achieved the highest accuracy (91.83%). Intra-model consistency was perfect (κ = 1). However, LLMs failed to assign CAD-RADS modifiers. ChatGPT-4o provided the most accurate follow-up recommendations (71.94%). All LLMs outperformed radiologists in execution time (3-9 s vs. 15-20 s; p < 0.05). CONCLUSIONS: Generic LLMs demonstrate promising performance in automating CAD-RADS 2.0 classification from CCTA reports. However, limitations in modifier assignment and recommendation accuracy highlight areas for refinement before clinical integration. CRITICAL RELEVANCE STATEMENT: This study explores the potential of large language models to facilitate standardized CAD-RADS 2.0 reporting from coronary CT angiography, highlighting a possible avenue to support workflow efficiency and clinical decision-making in non-invasive coronary artery disease evaluation. KEY POINTS: LLMs demonstrated strong potential in automating CAD-RADS 2.0-compliant structured reporting for CCTA. LLMs could significantly enhance efficiency in radiological reporting. LLMs need further optimization before clinical integration.

Authors

Institutions

Publication Details

Journal
Insights into Imaging
Published
2026-04-22
DOI
https://doi.org/10.1186/s13244-026-02285-6
Primary Topic
Radiology practices and education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of large language models for generating CAD-RADS 2.0-compliant diagnostic conclusions in cardiac CT reports

Ilaria Villanova, Nicola Maria Lucarelli, Chiara Morelli, Alessia Spitaleri et al.
Insights into Imaging
Radiology practices and education
article

Comparative evaluation of large language models for generating CAD-RADS 2.0-compliant diagnostic conclusions in cardiac CT reports

Ilaria Villanova, Nicola Maria Lucarelli, Chiara Morelli, Alessia Spitaleri, Nicola Maggialetti, Amato Antonio Stabile Ianora, Sara Greco, Giorgio Ruscino, Giovanni Lorusso, Michele Mariano
article en

Abstract

OBJECTIVES: Coronary computed tomography angiography (CCTA) has become a cornerstone in non-invasive CAD diagnosis and risk stratification. To standardize reporting and improve clinical decision-making, the CAD-RADS 2.0 system was introduced. This study evaluates the performance of four LLMs, GPT-4o, Gemini 2.0 Flash, DeepSeek V, and Copilot in generating CAD-RADS 2.0-compliant conclusions from standardized CCTA reports. MATERIALS AND METHODS: A total of 196 anonymized CCTA reports were retrospectively analyzed. Each LLM was prompted to provide CAD-RADS 2.0 classifications and follow-up recommendations. Ground truth labels were assigned by a senior radiologist. Performance metrics (accuracy, precision, recall, F1-score), execution times, and agreement (Cohen's kappa) with expert interpretation were computed. Interobserver agreement between junior and senior radiologists was also assessed. RESULTS: LLMs demonstrated good-to-excellent agreement with expert classifications: DeepSeek V (κ = 0.771), Copilot (κ = 0.761), GPT-4o (κ = 0.759), and Gemini 2.0 Flash (κ = 0.634). DeepSeek V achieved the highest accuracy (91.83%). Intra-model consistency was perfect (κ = 1). However, LLMs failed to assign CAD-RADS modifiers. ChatGPT-4o provided the most accurate follow-up recommendations (71.94%). All LLMs outperformed radiologists in execution time (3-9 s vs. 15-20 s; p < 0.05). CONCLUSIONS: Generic LLMs demonstrate promising performance in automating CAD-RADS 2.0 classification from CCTA reports. However, limitations in modifier assignment and recommendation accuracy highlight areas for refinement before clinical integration. CRITICAL RELEVANCE STATEMENT: This study explores the potential of large language models to facilitate standardized CAD-RADS 2.0 reporting from coronary CT angiography, highlighting a possible avenue to support workflow efficiency and clinical decision-making in non-invasive coronary artery disease evaluation. KEY POINTS: LLMs demonstrated strong potential in automating CAD-RADS 2.0-compliant structured reporting for CCTA. LLMs could significantly enhance efficiency in radiological reporting. LLMs need further optimization before clinical integration.

Insights into ImagingVol. 17(1)
University of Bari Aldo Moro (IT)
Openalex Percentile: Top 15%
Radiology practices and education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.