Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment

Surface electromyography (sEMG) is widely used to assess muscle activity in clinical and research settings. However, while conventional wet electrodes have advanced considerably in recent years, they are often limited by disposability, reduced comfort, and limited reusability. Recent advances in additive manufacturing provide opportunities to fabricate customizable, low-cost dry electrodes using conductive filaments. This study aimed to evaluate the feasibility and signal performance of in-house-fabricated 3D-printed sEMG electrodes made from three commercially available conductive filaments, (Fili, Filaflex, and Proto-Pasta) differing in base polymer and resistivity, and compared their performance with standard wet electrodes. Surface electrodes were placed over the biceps brachii muscle, and EMG signals were recorded during concentric–eccentric elbow flexion under three loading conditions (3, 5, and 7 kg). Signal quality was assessed using EMG amplitude, signal-to-noise ratio (SNR), and background noise. The results showed no significant differences in SNR or background noise between the 3D-printed electrodes and standard wet electrodes. Among the tested materials, Proto-Pasta electrodes produced the highest mean EMG amplitudes, while Filaflex electrodes showed slightly lower background noise, although these differences were not statistically significant. Overall, the findings indicate that in-house-fabricated 3D-printed electrodes can provide signal quality comparable to conventional wet electrodes, supporting their potential use as low-cost and customizable alternatives for sEMG applications in research and wearable monitoring systems.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-04-22
DOI
https://doi.org/10.3390/mi17050504
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment

Khalid Alhussaini, Ahmed A. Aldohbeyb, Ahmad Zahid Rao, Alaa M. Albishi et al.
Micromachines
Muscle activation and electromyography studies
article

Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment

Khalid Alhussaini, Ahmed A. Aldohbeyb, Ahmad Zahid Rao, Alaa M. Albishi, Ziyad Aloqalaa, Ahmad O. Alokaily, Mohamed A. Almadi, Khalid I. Aloraini, Shahad N. Alshamlan, Fahed K. Alnawfal, Suhail S. Alshahrani
article en

Abstract

Surface electromyography (sEMG) is widely used to assess muscle activity in clinical and research settings. However, while conventional wet electrodes have advanced considerably in recent years, they are often limited by disposability, reduced comfort, and limited reusability. Recent advances in additive manufacturing provide opportunities to fabricate customizable, low-cost dry electrodes using conductive filaments. This study aimed to evaluate the feasibility and signal performance of in-house-fabricated 3D-printed sEMG electrodes made from three commercially available conductive filaments, (Fili, Filaflex, and Proto-Pasta) differing in base polymer and resistivity, and compared their performance with standard wet electrodes. Surface electrodes were placed over the biceps brachii muscle, and EMG signals were recorded during concentric–eccentric elbow flexion under three loading conditions (3, 5, and 7 kg). Signal quality was assessed using EMG amplitude, signal-to-noise ratio (SNR), and background noise. The results showed no significant differences in SNR or background noise between the 3D-printed electrodes and standard wet electrodes. Among the tested materials, Proto-Pasta electrodes produced the highest mean EMG amplitudes, while Filaflex electrodes showed slightly lower background noise, although these differences were not statistically significant. Overall, the findings indicate that in-house-fabricated 3D-printed electrodes can provide signal quality comparable to conventional wet electrodes, supporting their potential use as low-cost and customizable alternatives for sEMG applications in research and wearable monitoring systems.

MicromachinesVol. 17(5)
King Saud University (SA), The University of Texas Health Science Center at Houston (US)
King Saud University
Openalex Percentile: Top 12%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.