Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures

The reduction of the annual equivalent dose limit to the lens of the eye from 150 to 20 mSv has increased the need for reliable assessment of occupational eye lens exposure, particularly in interventional radiology. Lens absorbed dose is commonly evaluated either using a dosimeter near the eye or indirectly using chest dosimeter readings. Although the indirect approach is well established in interventional cardiology, its validity for procedures with different exposure geometries remains uncertain. This study evaluated the agreement between direct and indirect estimates of lens equivalent dose in haemodynamic, electrophysiological and gastroenterological procedures. Forty-one physicians were monitored using thermoluminescent dosimeters placed close to the eye and on the chest above the lead apron. Direct lens doses were compared with indirect estimates derived from chest dosimeter. Agreement was assessed using linear fitting, Pearson's correlation coefficients and analysis of variance. A total of 449 valid dosimetric pairs were analysed. A statistically significant correlation between direct and indirect lens dose estimates was observed for haemodynamic and electrophysiological procedures. The indirect lens dose estimates provided conservative estimates in approximately 80% of cases and never resulted in exceedance of the 20 mSv annual dose limit. In contrast, no significant correlation was found for endoscopic retrograde cholangiopancreatography procedures, where indirect estimates frequently underestimated lens dose due to non-frontal exposure geometry. These findings confirm that reliable and conservative assessment of eye lens dose estimates in interventional cardiology is possible when chest doses are well below regulatory limits. However, caution is required when extending its use to non-cardiac procedures, where procedure-specific exposure conditions may compromise the reliability of lens dose estimates.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-04-21
DOI
https://doi.org/10.1088/1361-6498/ae6277
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures

L.N. Mazzoni, L. Redapi, Andrea Magistrelli, Francesco Meucci et al.
Journal of Radiological Protection
Radiation Dose and Imaging
article

Direct and indirect assessment: comparison of different methods to estimate staff equivalent dose to the lens during different interventional procedures

L.N. Mazzoni, L. Redapi, Andrea Magistrelli, Francesco Meucci, S. Bicchi, Stefania Fabiani, A. Vaiano, M. Betti, David Fedele, Luca Bernardi, Zeno Zoppi, Luca Fedeli
article en

Abstract

The reduction of the annual equivalent dose limit to the lens of the eye from 150 to 20 mSv has increased the need for reliable assessment of occupational eye lens exposure, particularly in interventional radiology. Lens absorbed dose is commonly evaluated either using a dosimeter near the eye or indirectly using chest dosimeter readings. Although the indirect approach is well established in interventional cardiology, its validity for procedures with different exposure geometries remains uncertain. This study evaluated the agreement between direct and indirect estimates of lens equivalent dose in haemodynamic, electrophysiological and gastroenterological procedures. Forty-one physicians were monitored using thermoluminescent dosimeters placed close to the eye and on the chest above the lead apron. Direct lens doses were compared with indirect estimates derived from chest dosimeter. Agreement was assessed using linear fitting, Pearson's correlation coefficients and analysis of variance. A total of 449 valid dosimetric pairs were analysed. A statistically significant correlation between direct and indirect lens dose estimates was observed for haemodynamic and electrophysiological procedures. The indirect lens dose estimates provided conservative estimates in approximately 80% of cases and never resulted in exceedance of the 20 mSv annual dose limit. In contrast, no significant correlation was found for endoscopic retrograde cholangiopancreatography procedures, where indirect estimates frequently underestimated lens dose due to non-frontal exposure geometry. These findings confirm that reliable and conservative assessment of eye lens dose estimates in interventional cardiology is possible when chest doses are well below regulatory limits. However, caution is required when extending its use to non-cardiac procedures, where procedure-specific exposure conditions may compromise the reliability of lens dose estimates.

Journal of Radiological ProtectionVol. 46(2)
Bambino Gesù Children's Hospital (IT), Azienda Usl Toscana Centro (IT), Hospital of Prato (IT)
Quality Education
Openalex Percentile: Top 17%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.