Free‐Breathing <scp>3D</scp> Whole Heart and Aorta Cine <scp>MRI</scp> Without Contrast Agent—Comparison to Clinical Standard

BACKGROUND: The demand for cardiac MRI is increasing with the growing burden of cardiovascular disease. However, conventional protocols require sequential acquisitions for multi-breath-hold 2D cine and 3D MR angiography (MRA), which is time-consuming. In addition, breath-hold 2D cine can be challenging for patients with limited breath-hold capacity. PURPOSE: To further develop and evaluate a free-breathing 3D whole-heart cine MRI technique for simultaneous assessment of cardiac function and aortic anatomy in a single non-contrast acquisition at 1.5 T. STUDY TYPE: Prospective. SUBJECTS: Twenty-four healthy volunteers (mean age 31.8 ± 9.9 years, 50% female). FIELD STRENGTH/SEQUENCES: 1.5 T; A cartesian spiral (CASPR) bSSFP 3D cine, 2D cine and 3D mDixon MRA. ASSESSMENT: Acquisition and reconstruction times were assessed for 3D cine at 2.5 and 2.0 mm. LV mass, LVEF, and RVEF were assessed by two observers (5 and 32 years of experience) and compared with 2D cine. Aortic root and ascending aortic areas were compared with 3D MRA. Image quality was evaluated using blood pool-to-myocardium contrast ratio and endocardial/epicardial edge sharpness. Qualitative image preference was assessed by three observers (5, 32, and 33 years of experience). STATISTICAL TESTS: One-way ANOVA with Tukey post hoc tests and Bland-Altman analysis with paired t-tests were used. Intraclass correlation coefficient (ICC) assessed inter- and intra-observer agreement. p < 0.05 was considered significant. RESULTS: , p < 0.001), while aortic root areas showed no difference versus 3D MRA. Reproducibility was at least moderate (ICC 0.75-0.998). 3D cine showed lower contrast and edge sharpness than 2D cine (p < 0.001). Observers preferred 2.0 mm (ICC = 0.64). DATA CONCLUSION: Free-breathing 3D cine MRI enables operator-independent, time-efficient, and accurate assessment of cardiac function and aortic anatomy in healthy volunteers in a single non-contrast acquisition at 1.5 T, compared to conventional 2D cine and 3D MRA. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance Imaging
Published
2026-04-20
DOI
https://doi.org/10.1002/jmri.70343
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Free‐Breathing 3D Whole Heart and Aorta Cine MRI Without Contrast Agent—Comparison to Clinical Standard

Jakob Meineke, Jochen Keupp, Merlijn Sevenster, Jos J.M. Westenberg et al.
Journal of Magnetic Resonance Imaging
Cardiac Imaging and Diagnostics
article

Free‐Breathing 3D Whole Heart and Aorta Cine MRI Without Contrast Agent—Comparison to Clinical Standard

Jakob Meineke, Jochen Keupp, Merlijn Sevenster, Jos J.M. Westenberg, Hildo J. Lamb, Alexandru Cernicanu, Huangling Lu, Ruixin Chen
article en

Abstract

BACKGROUND: The demand for cardiac MRI is increasing with the growing burden of cardiovascular disease. However, conventional protocols require sequential acquisitions for multi-breath-hold 2D cine and 3D MR angiography (MRA), which is time-consuming. In addition, breath-hold 2D cine can be challenging for patients with limited breath-hold capacity. PURPOSE: To further develop and evaluate a free-breathing 3D whole-heart cine MRI technique for simultaneous assessment of cardiac function and aortic anatomy in a single non-contrast acquisition at 1.5 T. STUDY TYPE: Prospective. SUBJECTS: Twenty-four healthy volunteers (mean age 31.8 ± 9.9 years, 50% female). FIELD STRENGTH/SEQUENCES: 1.5 T; A cartesian spiral (CASPR) bSSFP 3D cine, 2D cine and 3D mDixon MRA. ASSESSMENT: Acquisition and reconstruction times were assessed for 3D cine at 2.5 and 2.0 mm. LV mass, LVEF, and RVEF were assessed by two observers (5 and 32 years of experience) and compared with 2D cine. Aortic root and ascending aortic areas were compared with 3D MRA. Image quality was evaluated using blood pool-to-myocardium contrast ratio and endocardial/epicardial edge sharpness. Qualitative image preference was assessed by three observers (5, 32, and 33 years of experience). STATISTICAL TESTS: One-way ANOVA with Tukey post hoc tests and Bland-Altman analysis with paired t-tests were used. Intraclass correlation coefficient (ICC) assessed inter- and intra-observer agreement. p < 0.05 was considered significant. RESULTS: , p < 0.001), while aortic root areas showed no difference versus 3D MRA. Reproducibility was at least moderate (ICC 0.75-0.998). 3D cine showed lower contrast and edge sharpness than 2D cine (p < 0.001). Observers preferred 2.0 mm (ICC = 0.64). DATA CONCLUSION: Free-breathing 3D cine MRI enables operator-independent, time-efficient, and accurate assessment of cardiac function and aortic anatomy in healthy volunteers in a single non-contrast acquisition at 1.5 T, compared to conventional 2D cine and 3D MRA. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.

Journal of Magnetic Resonance Imaging
NXP (Netherlands) (NL), Leiden University Medical Center (NL), Amsterdam University Medical Centers (NL), Philips (Germany) (DE), University of Amsterdam (NL)
Zero hunger
Openalex Percentile: Top 14%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.