A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method

In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-04-21
DOI
https://doi.org/10.3390/en19082003
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method

S Q Wang, Linhong Yue, Hao Yang
Energies
Power Transformer Diagnostics and Insulation
article

A Simplified Temperature Field Calculation Model for Oil-Immersed Transformers Based on the FVM-POD Field–Circuit Coupling Method

S Q Wang, Linhong Yue, Hao Yang
article en

Abstract

In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications.

EnergiesVol. 19(8)
Chongqing University (CN)
Responsible consumption and production
Openalex Percentile: Top 18%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.