Digital measurement and safety parameter analysis of the infra-acetabular screw pathway

To evaluate acetabular anatomy using digital technology, determine the limiting parameters for infra-acetabular screw placement in the Chinese population, and provide a theoretical basis for clinical surgery. We collected CT data from 100 adult pelvic plain scans performed at the Affiliated Hospital of Xinjiang Medical University between 2020 and 2023. Three-dimensional models were reconstructed using Mimics software. The mid-pubic axial projection area was identified at the pelvic inlet. Simulated screw insertion procedures measured the following parameters: length and diameterthe of screw, medial distance (OA) and anterior distance (AP) from the entry point to the apex of the iliopubic eminence, as well as the angles formed by the screw axis with the pelvic coronal and sagittal planes. The mean length of the infra-acetabular screw pathway was 101.51 ± 4.87 mm in males and 91.63 ± 3.64 mm in females. The maximum screw diameter was 5.39 ± 1.25 mm in males and 4.55 ± 0.89 mm in females.The medial distance from the entry point to the iliopubic eminence was 11.09 ± 2.70 mm in males and 11.47 ± 3.46 mm in females; the anterolateral distance was 8.22 ± 3.68 mm in males and 7.32 ± 2.66 mm in females.The angle between the screw axis below the acetabulum and the coronal plane was 55.20° ± 5.40° in males and 53.30° ± 6.30° in females. The angle with the sagittal plane was 12.60° ± 9.80° in males and 2.60° ± 8.80° in females. Except for the angle with the coronal plane and the OA and AP value, all other parameters showed significant gender differences (P < 0.01).Among the 100 pelvic models collected in this study, 47 cases had a minimum screw insertion channel diameter ≥ 5 mm; while 5 cases had a minimum screw insertion diameter < 3.5 mm (1 male, 4 females). This study demonstrates gender-dependent differences in both screw length and maximum diameter within the infra-acetabular approach. We recommend preoperative 3D reconstruction simulation to determine safe and effective maximum channel parameters for infra-acetabular screw placement.

Authors

Institutions

Publication Details

Journal
BMC Surgery
Published
2026-04-22
DOI
https://doi.org/10.1186/s12893-026-03745-y
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital measurement and safety parameter analysis of the infra-acetabular screw pathway

Maimaiaili Yushan, Tongzhang Yang, Anker Nuermaimaiti, Askar Yasen et al.
BMC Surgery
Orthopaedic implants and arthroplasty
article

Digital measurement and safety parameter analysis of the infra-acetabular screw pathway

Maimaiaili Yushan, Tongzhang Yang, Anker Nuermaimaiti, Askar Yasen, Chao Ma, Zhiqiang Ma, Gang Lv
article en

Abstract

To evaluate acetabular anatomy using digital technology, determine the limiting parameters for infra-acetabular screw placement in the Chinese population, and provide a theoretical basis for clinical surgery. We collected CT data from 100 adult pelvic plain scans performed at the Affiliated Hospital of Xinjiang Medical University between 2020 and 2023. Three-dimensional models were reconstructed using Mimics software. The mid-pubic axial projection area was identified at the pelvic inlet. Simulated screw insertion procedures measured the following parameters: length and diameterthe of screw, medial distance (OA) and anterior distance (AP) from the entry point to the apex of the iliopubic eminence, as well as the angles formed by the screw axis with the pelvic coronal and sagittal planes. The mean length of the infra-acetabular screw pathway was 101.51 ± 4.87 mm in males and 91.63 ± 3.64 mm in females. The maximum screw diameter was 5.39 ± 1.25 mm in males and 4.55 ± 0.89 mm in females.The medial distance from the entry point to the iliopubic eminence was 11.09 ± 2.70 mm in males and 11.47 ± 3.46 mm in females; the anterolateral distance was 8.22 ± 3.68 mm in males and 7.32 ± 2.66 mm in females.The angle between the screw axis below the acetabulum and the coronal plane was 55.20° ± 5.40° in males and 53.30° ± 6.30° in females. The angle with the sagittal plane was 12.60° ± 9.80° in males and 2.60° ± 8.80° in females. Except for the angle with the coronal plane and the OA and AP value, all other parameters showed significant gender differences (P < 0.01).Among the 100 pelvic models collected in this study, 47 cases had a minimum screw insertion channel diameter ≥ 5 mm; while 5 cases had a minimum screw insertion diameter < 3.5 mm (1 male, 4 females). This study demonstrates gender-dependent differences in both screw length and maximum diameter within the infra-acetabular approach. We recommend preoperative 3D reconstruction simulation to determine safe and effective maximum channel parameters for infra-acetabular screw placement.

BMC Surgery
Urumqi General Hospital of PLA (CN)
Science and Technology Department of Xinjiang Uygur Autonomous Region, Xinjiang Medical University
Affordable and clean energy
Openalex Percentile: Top 8%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.