Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties

Abstract A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10 –4 mol L –1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness.

Authors

Institutions

Publication Details

Journal
Polymer Journal
Published
2026-04-21
DOI
https://doi.org/10.1038/s41428-026-01170-9
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties

Shinji Ando, Yoshihiko Tashiro, Hidekazu Yasunaga
Polymer Journal
Hemostasis and retained surgical items
article

Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties

Shinji Ando, Yoshihiko Tashiro, Hidekazu Yasunaga
article en

Abstract

Abstract A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10 –4 mol L –1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness.

Polymer Journal
Tokyo Institute of Technology (JP), SHOWA Medical University (JP), Kyoto Institute of Technology (JP)
Clean water and sanitation
Openalex Percentile: Top 6%
Hemostasis and retained surgical items
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.