New Possibilities of Testing the Darkening of Automatic Welding Filters as Expressed by Switching Time

Welders constitute an occupational group that is particularly exposed to high-risk hazards arising from harmful radiation emitted during welding, including ultraviolet (UV) and infrared (IR) radiation, as well as visible (VIS) radiation, whose high intensity causes glare. Effective protection of the eyes and face is provided by welding shields equipped with automatic welding filters (AWFs), which activate automatically upon arc ignition. Their switching time is the most important protective parameter, as it has a direct impact on the user’s visual health. The objective of the work is to present a novel test stand for determining AWFs switching and holding times, which provides advanced possibilities for evaluating all types of AWFs. Until now, performance and safety levels have been determined based on numerical values: switching time and hold time. For the first time, it is possible to analyze the darkening and clearing phenomena over time with an interpretation of graphical results. Importantly, it is possible to analyze the symmetry of filter properties, using two measurement channels, which is crucial for binocular and curved (panoramic) AWFs. The results obtained for two types of AWFs mounted in goggles with a one-piece and a binocular visor differ from each other. Switching time differences between the left and right measurement channels were about 6–7% for the one-piece visor goggles (G1) and about 3–4% for the binocular goggles (G2). The dispersion of results confirmed the importance of the two measurement channels, which was not previously practiced. The test stand, designed in accordance with the requirements of the new European standards (EN ISO 18526-2:2020, EN ISO 16321-2:2021), can be used for prototyping and for AWF certification purposes.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-04-21
DOI
https://doi.org/10.3390/app16084045
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Possibilities of Testing the Darkening of Automatic Welding Filters as Expressed by Switching Time

Joanna Szkudlarek, Marcin Jachowicz
Applied Sciences
Ocular and Laser Science Research
article

New Possibilities of Testing the Darkening of Automatic Welding Filters as Expressed by Switching Time

Joanna Szkudlarek, Marcin Jachowicz
article en

Abstract

Welders constitute an occupational group that is particularly exposed to high-risk hazards arising from harmful radiation emitted during welding, including ultraviolet (UV) and infrared (IR) radiation, as well as visible (VIS) radiation, whose high intensity causes glare. Effective protection of the eyes and face is provided by welding shields equipped with automatic welding filters (AWFs), which activate automatically upon arc ignition. Their switching time is the most important protective parameter, as it has a direct impact on the user’s visual health. The objective of the work is to present a novel test stand for determining AWFs switching and holding times, which provides advanced possibilities for evaluating all types of AWFs. Until now, performance and safety levels have been determined based on numerical values: switching time and hold time. For the first time, it is possible to analyze the darkening and clearing phenomena over time with an interpretation of graphical results. Importantly, it is possible to analyze the symmetry of filter properties, using two measurement channels, which is crucial for binocular and curved (panoramic) AWFs. The results obtained for two types of AWFs mounted in goggles with a one-piece and a binocular visor differ from each other. Switching time differences between the left and right measurement channels were about 6–7% for the one-piece visor goggles (G1) and about 3–4% for the binocular goggles (G2). The dispersion of results confirmed the importance of the two measurement channels, which was not previously practiced. The test stand, designed in accordance with the requirements of the new European standards (EN ISO 18526-2:2020, EN ISO 16321-2:2021), can be used for prototyping and for AWF certification purposes.

Applied SciencesVol. 16(8)
Central Institute for Labour Protection (PL)
Openalex Percentile: Top 12%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

New Possibilities of Testing the Darkening of Automatic Welding Filters as Expressed by Switching Time — Joanna Szkudlarek, Marcin Jachowicz · Applied Sciences (2026) | TGRS Research Map | TGRS