Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics

Seven popular C18 stationary phases for peptide separation in bottom-up proteomics have been evaluated based on overall peptide retention, column backpressure, separation selectivity and efficiency, number of peptide identifications, and carryover statistics. Under standard 0.1% formic acid water-acetonitrile elution conditions, peptide retention varies within an elution range of ∼3.4% acetonitrile and increases in the following order: XSelect CSH C18 2.5 μm, 130 Å < Luna C18(2) 3 μm, 100 Å < PepMap RSLC C18 2 μm, 100 Å ≪ Reprosil-Pur ODS-3 3 μm, 120 Å < Reprosil-Pur C18 AQ 3 μm, 120 Å < Magic C18 AQ 3 μm, 200 Å < XBridge BEH C18 2.5 μm, 130 Å. While the lower retention on the XSelect was expected due to the embedded positively charged groups, the behavior of Luna C18(2) and PepMap C18 can be explained by the reduction of surface accessibility for small pore size matrices. Pore size was a major contributor to varying separation selectivity. The number of unique peptide identifications is driven by peptide separation efficiency and retentivity. These factors favor sorbents with smaller particle sizes and higher retentivity, such as XBridge BEH C18. Low peptide retentivity and average separation efficiency diminish identification output for Luna C18(2) and PepMap RSLC with 100 Å pore size.

Authors

Institutions

Publication Details

Journal
Journal of Proteome Research
Published
2026-04-21
DOI
https://doi.org/10.1021/acs.jproteome.5c01175
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics

Oleg V. Krokhin, Ying Lao, René P. Zahedi, V Spicer et al.
Journal of Proteome Research
Protein purification and stability
article

Selection of Reversed-Phase C18 Separation Media for Bottom-Up Proteomics: Multifactor Comparison of Fully Porous Sorbents Including Separation Selectivity and Carryover Characteristics

Oleg V. Krokhin, Ying Lao, René P. Zahedi, V Spicer, Darien Yeung, Joao Paulo
article en

Abstract

Seven popular C18 stationary phases for peptide separation in bottom-up proteomics have been evaluated based on overall peptide retention, column backpressure, separation selectivity and efficiency, number of peptide identifications, and carryover statistics. Under standard 0.1% formic acid water-acetonitrile elution conditions, peptide retention varies within an elution range of ∼3.4% acetonitrile and increases in the following order: XSelect CSH C18 2.5 μm, 130 Å < Luna C18(2) 3 μm, 100 Å < PepMap RSLC C18 2 μm, 100 Å ≪ Reprosil-Pur ODS-3 3 μm, 120 Å < Reprosil-Pur C18 AQ 3 μm, 120 Å < Magic C18 AQ 3 μm, 200 Å < XBridge BEH C18 2.5 μm, 130 Å. While the lower retention on the XSelect was expected due to the embedded positively charged groups, the behavior of Luna C18(2) and PepMap C18 can be explained by the reduction of surface accessibility for small pore size matrices. Pore size was a major contributor to varying separation selectivity. The number of unique peptide identifications is driven by peptide separation efficiency and retentivity. These factors favor sorbents with smaller particle sizes and higher retentivity, such as XBridge BEH C18. Low peptide retentivity and average separation efficiency diminish identification output for Luna C18(2) and PepMap RSLC with 100 Å pore size.

Journal of Proteome ResearchVol. 25(5)
Harvard University (US), University of Manitoba (CA)
University of Manitoba, Natural Sciences and Engineering Research Council of Canada, Common Fund
Zero hunger
Openalex Percentile: Top 19%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.