Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary Angiography

BACKGROUND: Percutaneous coronary intervention (PCI) is a cornerstone treatment for coronary artery disease. As procedural volumes continue to rise, the associated radiation risk from angiography systems has drawn increasing concern. Thus, we developed a novel ultra-low-dose Noise-Free technology to optimize angiography systems. This study aims to investigate whether it effectively reduces radiation exposure in real-world coronary interventions. METHODS: A comparative study on a single-center, real-world, observational cohort. The primary end point was an intergroup comparison of procedural radiation exposure, including dose area product, air kerma, and dose rate, stratified by exposure mode (fluoroscopy or cine) and procedure type (diagnostic coronary angiography, single-vessel PCI, or chronic total occlusion PCI). The secondary end point included an expert semi-quantitative assessment and a quantitative contrast-to-noise ratio for image quality. RESULTS: , fluoroscopy dose rate of 7.9 (6.0-9.6) mGy/min, and cine dose rate of 51.7 (37.4-64.9) mGy/min, corresponding to 40% to 70%, 37% to 66%, 16% to 62%, and 25% to 79% reductions than others, respectively. Similar radiation reductions were observed for single-vessel PCI. For chronic total occlusion PCI, the corresponding percentages of radiation reduction in total air kerma, total dose area product, fluoroscopy dose rate, and cine dose rate were 59% to 73%, 54% to 69%, 22% to 64%, and 60% to 79%, respectively, relative to the other 3 systems. The semi-quantitative assessment and contrast-to-noise ratio analysis showed comparable image quality between the 4 systems. CONCLUSIONS: The Noise-Free technique reduced radiation exposure across cumulative and rate metrics while preserving diagnostic image quality, with the greatest reduction observed in complex cases. These findings support its clinical utility for lowering radiation risk.

Authors

Institutions

Publication Details

Journal
Circulation Cardiovascular Interventions
Published
2026-04-21
DOI
https://doi.org/10.1161/circinterventions.126.016542
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary Angiography

J Y, Feng Zhang, J Y Qian, Z W Chen et al.
Circulation Cardiovascular Interventions
Radiation Dose and Imaging
article

Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary Angiography

J Y, Feng Zhang, J Y Qian, Z W Chen, R A N Xu, Qiyu Zhang, Chenguang Li, Junbo Ge
article en

Abstract

BACKGROUND: Percutaneous coronary intervention (PCI) is a cornerstone treatment for coronary artery disease. As procedural volumes continue to rise, the associated radiation risk from angiography systems has drawn increasing concern. Thus, we developed a novel ultra-low-dose Noise-Free technology to optimize angiography systems. This study aims to investigate whether it effectively reduces radiation exposure in real-world coronary interventions. METHODS: A comparative study on a single-center, real-world, observational cohort. The primary end point was an intergroup comparison of procedural radiation exposure, including dose area product, air kerma, and dose rate, stratified by exposure mode (fluoroscopy or cine) and procedure type (diagnostic coronary angiography, single-vessel PCI, or chronic total occlusion PCI). The secondary end point included an expert semi-quantitative assessment and a quantitative contrast-to-noise ratio for image quality. RESULTS: , fluoroscopy dose rate of 7.9 (6.0-9.6) mGy/min, and cine dose rate of 51.7 (37.4-64.9) mGy/min, corresponding to 40% to 70%, 37% to 66%, 16% to 62%, and 25% to 79% reductions than others, respectively. Similar radiation reductions were observed for single-vessel PCI. For chronic total occlusion PCI, the corresponding percentages of radiation reduction in total air kerma, total dose area product, fluoroscopy dose rate, and cine dose rate were 59% to 73%, 54% to 69%, 22% to 64%, and 60% to 79%, respectively, relative to the other 3 systems. The semi-quantitative assessment and contrast-to-noise ratio analysis showed comparable image quality between the 4 systems. CONCLUSIONS: The Noise-Free technique reduced radiation exposure across cumulative and rate metrics while preserving diagnostic image quality, with the greatest reduction observed in complex cases. These findings support its clinical utility for lowering radiation risk.

Circulation Cardiovascular Interventions
JDA Software (United States) (US), Fudan University (CN)
Good health and well-being
Openalex Percentile: Top 10%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.