Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge

Vacuum degree inside vacuum interrupter (VI) deteriorates due to cracks from long-term operation of VI, gas emitted from internal arc heat, leakage through the joint, etc. Partial discharge occurs between the two contacts inside the VI or between the contact and floating shield, which leads to dielectric breakdown and electrical accidents of high voltage apparatus. In this paper, the study on the vacuum degree monitoring of distribution class vacuum interrupter according to non-contact method of coupling capacitor based on partial discharge was performed. In order to monitor the partial discharge between two contacts inside VI with high accuracy, a partial discharge sensing electrode (PDDE) was designed using the 3D finite element method (FEM). In addition, after calculating the internal capacitance according to the structure and size characteristics inside VI, the capacity of the coupling capacitor to detect the signal was calculated. The partial discharge characteristics according to the vacuum degree were analyzed by applying PDDE and a coupling capacitor. As results, it was found that the partial discharge characteristics inside VI differ depending on the voltage type. In addition, it was confirmed that even if VI has the same internal structure and size, the partial discharge characteristics appear differently. Based on the experimental results, we proposed maintenance criteria for VI for each voltage type.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-04-21
DOI
https://doi.org/10.3390/en19082005
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge

Seungmin Bang, B E. Lee, Chanyeol Ryu
Energies
Vacuum and Plasma Arcs
article

Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge

Seungmin Bang, B E. Lee, Chanyeol Ryu
article en

Abstract

Vacuum degree inside vacuum interrupter (VI) deteriorates due to cracks from long-term operation of VI, gas emitted from internal arc heat, leakage through the joint, etc. Partial discharge occurs between the two contacts inside the VI or between the contact and floating shield, which leads to dielectric breakdown and electrical accidents of high voltage apparatus. In this paper, the study on the vacuum degree monitoring of distribution class vacuum interrupter according to non-contact method of coupling capacitor based on partial discharge was performed. In order to monitor the partial discharge between two contacts inside VI with high accuracy, a partial discharge sensing electrode (PDDE) was designed using the 3D finite element method (FEM). In addition, after calculating the internal capacitance according to the structure and size characteristics inside VI, the capacity of the coupling capacitor to detect the signal was calculated. The partial discharge characteristics according to the vacuum degree were analyzed by applying PDDE and a coupling capacitor. As results, it was found that the partial discharge characteristics inside VI differ depending on the voltage type. In addition, it was confirmed that even if VI has the same internal structure and size, the partial discharge characteristics appear differently. Based on the experimental results, we proposed maintenance criteria for VI for each voltage type.

EnergiesVol. 19(8)
Korea Electrotechnology Research Institute (KR), Hanyang University (KR)
Ministry of Trade, Industry and Energy, Korea Institute of Energy Technology Evaluation and Planning
Openalex Percentile: Top 15%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.