LC-MS/MS of PEth in whole blood: implementation in routine clinical chemistry

In clinical practice, assessing alcohol intake can be challenging because patients may under-report or misjudge their consumption, so biomarkers of chronic intake provide valuable additional information. Phosphatidylethanol (PEth) is a group of abnormal phospholipids that are formed in cell membranes only in the presence of ethanol (alcohol). We developed, analytically validated, and clinically implemented a rapid and robust LC-MS/MS-based method for quantifying PEth (16:0/18:1) in whole blood. The method demonstrates a limit of detection (LOD) of 0.01 μM and a limit of quantification (LOQ) of 0.03 μM, with confirmed linearity up to at least 0.8 μM. Validation using reference materials and samples from patients with liver disease and self-reported alcohol intake confirmed its accuracy. Clinical implementation over a two-month period, involving 20 analytical batches, demonstrated inter-assay precision below 15%. Our results support the clinical applicability of PEth use for accurate estimation of alcohol intake in humans.

Authors

Institutions

Publication Details

Journal
Practical Laboratory Medicine
Published
2026-04-21
DOI
https://doi.org/10.1016/j.plabm.2026.e00533
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LC-MS/MS of PEth in whole blood: implementation in routine clinical chemistry

Jakob Albrethsen
Practical Laboratory Medicine
Pesticide Residue Analysis and Safety
article

LC-MS/MS of PEth in whole blood: implementation in routine clinical chemistry

Jakob Albrethsen
article en

Abstract

In clinical practice, assessing alcohol intake can be challenging because patients may under-report or misjudge their consumption, so biomarkers of chronic intake provide valuable additional information. Phosphatidylethanol (PEth) is a group of abnormal phospholipids that are formed in cell membranes only in the presence of ethanol (alcohol). We developed, analytically validated, and clinically implemented a rapid and robust LC-MS/MS-based method for quantifying PEth (16:0/18:1) in whole blood. The method demonstrates a limit of detection (LOD) of 0.01 μM and a limit of quantification (LOQ) of 0.03 μM, with confirmed linearity up to at least 0.8 μM. Validation using reference materials and samples from patients with liver disease and self-reported alcohol intake confirmed its accuracy. Clinical implementation over a two-month period, involving 20 analytical batches, demonstrated inter-assay precision below 15%. Our results support the clinical applicability of PEth use for accurate estimation of alcohol intake in humans.

Practical Laboratory MedicineVol. 50
University of Copenhagen (DK), Frederiksberg Hospital (DK), Hvidovre Hospital (DK), Copenhagen University Hospital (DK)
Novo Nordisk, Bispebjerg Hospital
Openalex Percentile: Top 21%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.