A multi-method explainability approach for sensor-based health activity analytics

Deep neural networks have become the dominant approach to wearable human activity recognition (HAR). Yet, their opacity creates practical barriers because clinicians cannot verify whether predictions align with physiological knowledge. Engineers lack principled guidance on which sensors to retain when cost and power constraints require system simplification. Existing explainable artificial intelligence (XAI) methods for wearable HAR typically rely on a single attribution technique, which introduces method-specific bias and reports importance at granularities such as individual channels or entire body locations that do not map cleanly to hardware design decisions. This study introduces a multi-method XAI framework that integrates counterfactual sensor group ablation, Integrated Gradients, and Shapley value sampling around a shared deep learning backbone and evaluates it using a time-distributed long short-term memory network trained on the Mobile Health dataset, which records twelve physical activities through eight sensor groups, including accelerometers, gyroscopes, magnetometers, and electrocardiogram signals at the chest, ankle, and wrist, achieving 98.2 percent accuracy and a macro-averaged F1 score of 0.98. Four coordinated experiments examine model behavior at global, sensor group, and activity-specific levels, showing that removing the ankle magnetometer reduces dynamic locomotion accuracy by 47.1 percentage points while removing the wrist accelerometer decreases confidence for static postures by more than 50 percent. Class-specific Integrated Gradients heatmaps and temporal attribution curves produce biomechanically consistent patterns such as ankle-centered signatures for gait and wrist and chest emphasis for upper body movements. Global Integrated Gradients and Shapley value rankings converge, with accelerometers accounting for 89 percent of the total attribution mass. The agreement across causal, gradient-based, and game-theoretic perspectives strengthens confidence that the identified sensor importance patterns reflect genuine model behavior, yielding sensor group-level explanations that provide actionable guidance for sensor selection, power-aware deployment, and clinically meaningful interpretation without sacrificing recognition performance. • Integrate multiple explainability methods to reveal sensor-driven health activity patterns. • Achieve highly accurate recognition for clinically relevant human activities. • Identify the most influential wearable sensors for health monitoring. • Quantify how sensor removal affects health activity recognition quality. • Provide analytics-driven guidance for power-efficient wearable health systems.

Authors

Institutions

Publication Details

Journal
Healthcare Analytics
Published
2026-04-21
DOI
https://doi.org/10.1016/j.health.2026.100463
Primary Topic
Explainable Artificial Intelligence (XAI)
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multi-method explainability approach for sensor-based health activity analytics

Muhammad Khaerul Naim Mursalim, Dani Lukman Hakim, Mochammad Ariyanto, Ade Kurniawan et al.
Healthcare Analytics
Explainable Artificial Intelligence (XAI)
article

A multi-method explainability approach for sensor-based health activity analytics

Muhammad Khaerul Naim Mursalim, Dani Lukman Hakim, Mochammad Ariyanto, Ade Kurniawan, Wahyu Caesarendra
article en

Abstract

Deep neural networks have become the dominant approach to wearable human activity recognition (HAR). Yet, their opacity creates practical barriers because clinicians cannot verify whether predictions align with physiological knowledge. Engineers lack principled guidance on which sensors to retain when cost and power constraints require system simplification. Existing explainable artificial intelligence (XAI) methods for wearable HAR typically rely on a single attribution technique, which introduces method-specific bias and reports importance at granularities such as individual channels or entire body locations that do not map cleanly to hardware design decisions. This study introduces a multi-method XAI framework that integrates counterfactual sensor group ablation, Integrated Gradients, and Shapley value sampling around a shared deep learning backbone and evaluates it using a time-distributed long short-term memory network trained on the Mobile Health dataset, which records twelve physical activities through eight sensor groups, including accelerometers, gyroscopes, magnetometers, and electrocardiogram signals at the chest, ankle, and wrist, achieving 98.2 percent accuracy and a macro-averaged F1 score of 0.98. Four coordinated experiments examine model behavior at global, sensor group, and activity-specific levels, showing that removing the ankle magnetometer reduces dynamic locomotion accuracy by 47.1 percentage points while removing the wrist accelerometer decreases confidence for static postures by more than 50 percent. Class-specific Integrated Gradients heatmaps and temporal attribution curves produce biomechanically consistent patterns such as ankle-centered signatures for gait and wrist and chest emphasis for upper body movements. Global Integrated Gradients and Shapley value rankings converge, with accelerometers accounting for 89 percent of the total attribution mass. The agreement across causal, gradient-based, and game-theoretic perspectives strengthens confidence that the identified sensor importance patterns reflect genuine model behavior, yielding sensor group-level explanations that provide actionable guidance for sensor selection, power-aware deployment, and clinically meaningful interpretation without sacrificing recognition performance. • Integrate multiple explainability methods to reveal sensor-driven health activity patterns. • Achieve highly accurate recognition for clinically relevant human activities. • Identify the most influential wearable sensors for health monitoring. • Quantify how sensor removal affects health activity recognition quality. • Provide analytics-driven guidance for power-efficient wearable health systems.

Healthcare AnalyticsVol. 9
Diponegoro University (ID), Higher Colleges of Technology (AE), Bandung Institute of Technology (ID), Universitas Riau Kepulauan (ID)
Openalex Percentile: Top 18%
Explainable Artificial Intelligence (XAI)
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.