Three-dimensional numerical modeling for assessing airborne infection risk in hospital waiting rooms with various ventilation approaches

Abstract Airborne infectious diseases, such as COVID-19, TB, MERS, and SARS, constitute a profound threat to public health and quality of life. These pathogens are transmitted primarily via atmospheric particles, especially within clinical environments, where they often circulate. Effective ventilation controls to mitigate pathogens and air pollution are thus essential for reducing hospital-based transmission of airborne infections. The purpose of this research is to assess the risk of airborne infectious diseases within a hospital in Thailand using a mathematical model. Specifically, the finite difference technique is employed to estimate carbon dioxide (CO 2 ) concentration as a proxy for indoor air quality to indicate and assess the risk of airborne infectious diseases. The hospital layout is categorized into waiting areas and circulation areas with disparate occupant densities. Three simulation scenarios are conducted, accounting for variations in ventilation rates and architectural structure of hospitals. The results of this research demonstrate that CO 2 concentration can be effectively quantified as a proxy for indoor air quality within hospital environments. These calculated CO 2 levels are subsequently used to model the risk of airborne infection at a hospital, providing a robust framework for assessing this risk. Crucially, by integrating ventilation dynamics that reflect the physical constraints and structure of the hospital, this research enables precise evaluation of infection risks. The findings indicate that ventilation control can reduce the incidence of airborne infection, with significant practical utility in real-world clinical settings.

Authors

Institutions

Publication Details

Journal
Modeling Earth Systems and Environment
Published
2026-04-21
DOI
https://doi.org/10.1007/s40808-026-02808-6
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-dimensional numerical modeling for assessing airborne infection risk in hospital waiting rooms with various ventilation approaches

Pravitra Oyjinda, Nopparat Pochai, Kewalee Suebyat, Jenjira Sooknum
Modeling Earth Systems and Environment
Infection Control and Ventilation
article

Three-dimensional numerical modeling for assessing airborne infection risk in hospital waiting rooms with various ventilation approaches

Pravitra Oyjinda, Nopparat Pochai, Kewalee Suebyat, Jenjira Sooknum
article en

Abstract

Abstract Airborne infectious diseases, such as COVID-19, TB, MERS, and SARS, constitute a profound threat to public health and quality of life. These pathogens are transmitted primarily via atmospheric particles, especially within clinical environments, where they often circulate. Effective ventilation controls to mitigate pathogens and air pollution are thus essential for reducing hospital-based transmission of airborne infections. The purpose of this research is to assess the risk of airborne infectious diseases within a hospital in Thailand using a mathematical model. Specifically, the finite difference technique is employed to estimate carbon dioxide (CO 2 ) concentration as a proxy for indoor air quality to indicate and assess the risk of airborne infectious diseases. The hospital layout is categorized into waiting areas and circulation areas with disparate occupant densities. Three simulation scenarios are conducted, accounting for variations in ventilation rates and architectural structure of hospitals. The results of this research demonstrate that CO 2 concentration can be effectively quantified as a proxy for indoor air quality within hospital environments. These calculated CO 2 levels are subsequently used to model the risk of airborne infection at a hospital, providing a robust framework for assessing this risk. Crucially, by integrating ventilation dynamics that reflect the physical constraints and structure of the hospital, this research enables precise evaluation of infection risks. The findings indicate that ventilation control can reduce the incidence of airborne infection, with significant practical utility in real-world clinical settings.

Modeling Earth Systems and EnvironmentVol. 12(3)
Chulabhorn Hospital (TH), Centre of Excellence in Mathematics (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Chulabhorn Royal Academy
Openalex Percentile: Top 8%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.