Advancing chloramphenicol detection through a novel porous organic polymer-enhanced screen-printed electrode

, a limit of detection of 1.67 μM, and a limit of quantification of 5 μM, along with good repeatability, selectivity, and operational stability over 30 days. Method validation was carried out using pharmaceutical products (topical suspensions, topical gels, injectable suspension, and eye drops) and animal biological samples (cow milk, cow urine and pig urine) containing CAP, yielding satisfactory analytical performance despite the complexity of the matrices and confirming the applicability of the proposed platform for real-sample analysis. These results demonstrate the potential of POPs as effective electrode modifiers for electrochemical sensors.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2026-04-20
DOI
https://doi.org/10.1016/j.talanta.2026.129873
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing chloramphenicol detection through a novel porous organic polymer-enhanced screen-printed electrode

Niculina D. Hădade, Mihaela Tertiş, Mihaela M. Trandafir, Florentina Neațu et al.
Talanta
Electrochemical sensors and biosensors
article

Advancing chloramphenicol detection through a novel porous organic polymer-enhanced screen-printed electrode

Niculina D. Hădade, Mihaela Tertiş, Mihaela M. Trandafir, Florentina Neațu, Cécilia Cristea, Cătălin C. Anghel, Mihaela Florea, Ede Bodoki, Maria Suciu, Daniel-Florin Bogoșel, Alexandra Pop, Ion Grosu, Iuliana M. Chirica, Anamaria Blaga Petrean, Paul C. Martian
article en

Abstract

, a limit of detection of 1.67 μM, and a limit of quantification of 5 μM, along with good repeatability, selectivity, and operational stability over 30 days. Method validation was carried out using pharmaceutical products (topical suspensions, topical gels, injectable suspension, and eye drops) and animal biological samples (cow milk, cow urine and pig urine) containing CAP, yielding satisfactory analytical performance despite the complexity of the matrices and confirming the applicability of the proposed platform for real-sample analysis. These results demonstrate the potential of POPs as effective electrode modifiers for electrochemical sensors.

TalantaVol. 308
Iuliu Hațieganu University of Medicine and Pharmacy (RO), University of Agricultural Sciences and Veterinary Medicine of Cluj-Napoca (RO), Babeș-Bolyai University (RO), National Institute of Materials Physics (RO), National Institute for Research and Development of Isotopic and Molecular Technologies (RO)
Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii
Openalex Percentile: Top 13%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.