A Portable Fluorometer for the Detection of Glyphosate

periplasmic binding protein PhnD was optimized through strategic fluorophore placement to produce a robust fluorescence signal increase upon glyphosate binding. The biosensor was integrated into a self-contained, 3D-printed device that functions as a miniature fluorometer, providing a simple yes-or-no output for non-expert users while retaining access to raw fluorescence data. The device exhibits nanomolar fluorescence sensitivity with results comparable to a benchtop fluorometer. Using this platform, glyphosate was reliably detected in buffered solutions, commercial herbicides, tap water, and soil extracts. To mitigate false positives arising from phosphate interference, we developed a dual-sensor strategy incorporating an independent phosphate biosensor and a second-generation device capable of multi-wavelength fluorescence detection. Together, these results demonstrate an affordable and versatile biosensing platform with strong potential for field-based environmental monitoring.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-04-20
DOI
https://doi.org/10.3390/bios16040225
Primary Topic
Pesticide and Herbicide Environmental Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Portable Fluorometer for the Detection of Glyphosate

Shahir S. Rizk, Owen K. Rizk, Adrian S. Rizk, Nathanael B. Smith
Biosensors
Pesticide and Herbicide Environmental Studies
article

A Portable Fluorometer for the Detection of Glyphosate

Shahir S. Rizk, Owen K. Rizk, Adrian S. Rizk, Nathanael B. Smith
article en

Abstract

periplasmic binding protein PhnD was optimized through strategic fluorophore placement to produce a robust fluorescence signal increase upon glyphosate binding. The biosensor was integrated into a self-contained, 3D-printed device that functions as a miniature fluorometer, providing a simple yes-or-no output for non-expert users while retaining access to raw fluorescence data. The device exhibits nanomolar fluorescence sensitivity with results comparable to a benchtop fluorometer. Using this platform, glyphosate was reliably detected in buffered solutions, commercial herbicides, tap water, and soil extracts. To mitigate false positives arising from phosphate interference, we developed a dual-sensor strategy incorporating an independent phosphate biosensor and a second-generation device capable of multi-wavelength fluorescence detection. Together, these results demonstrate an affordable and versatile biosensing platform with strong potential for field-based environmental monitoring.

BiosensorsVol. 16(4)
Indiana University South Bend (US)
Burroughs Wellcome Fund
Life in Land
Openalex Percentile: Top 20%
Pesticide and Herbicide Environmental Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.