The Potency of DCLGAN for Reducing Scan time in PET/CT imaging with different radiotracers of clinical importance

BACKGROUND AND PURPOSE: Shortening PET/CT acquisition without degrading diagnostic or quantitative performance would improve patient comfort and scanner throughput. We evaluated a Dual-Contrastive Learning GAN (DCLGAN) for reconstructing high-quality neuro-PET images from reduced-time acquisitions across three clinically used tracers (18F-florbetaben (FBB), 18F-FDG, and 18F-FP-CIT) benchmarking against representative state-of-the-art deep learning models. MATERIALS AND METHODS: In this single-center retrospective study of symptomatic patients undergoing neuro-PET/CT, list-mode data from full-time acquisitions (20 min for FBB; 15 min for FDG and FP-CIT) were reconstructed into 3- and 5-minute images. DCLGAN was trained to translate short-time to full-time appearance; raw images and standard 2.5D U-Net served as comparators. Image quality was quantified by normalized root-mean-square error (NRMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). Two blinded nuclear medicine physicians graded clinical image quality on a five-point scale; inter-reader agreement used Cohen's kappa. Quantitative agreement of standardized uptake value ratio (SUVR) for FBB/FDG and specific binding ratio (SBR) for FP-CIT between predicted and full-time images was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. RESULTS: With DCLGAN at 5 minutes, image-quality metrics approached full-time performance across tracers: for FBB, NRMSE 0.018, PSNR 34.721 dB, SSIM 0.963; for FP-CIT, NRMSE 0.008, PSNR 41.889 dB, SSIM 0.982; and for FDG, NRMSE 0.013, PSNR 37.502 dB, SSIM 0.986. Mean reader quality scores for 5-minute DCLGAN images were high-4.48 (FBB), 4.50 (FDG), and 4.55 (FP-CIT)-with strong inter-reader agreement (κ=0.85, 0.83, 0.89, respectively). Quantitative agreement with full-time scans was excellent: ICCs for 5-minute images were 0.997 (FBB), 0.995 (FDG), and 0.996 (FP-CIT). Bland-Altman analyses showed minimal bias (mean bias -0.004 for FBB, 0.012 for FDG, -0.029 for FP-CIT) with narrow limits of agreement. Compared with 3-minute reconstructions, 5-minute DCLGAN images demonstrated significantly higher PSNR/SSIM and lower NRMSE (p<0.001), while maintaining or improving reader scores and quantitative agreement. CONCLUSIONS: Across FBB, FDG, and FP-CIT, DCLGAN enabled 5-minute neuro-PET acquisitions that appeared to maintain reader-rated quality and showed high agreement in SUVR/SBR values with full-time scans. These findings suggest that clinically practical scan-time reduction may be feasible while maintaining interpretability and quantitative integrity in this cohort.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-04-20
DOI
https://doi.org/10.3174/ajnr.a9360
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Potency of DCLGAN for Reducing Scan time in PET/CT imaging with different radiotracers of clinical importance

Yeojun Yun, Mijin Yun, Seungbeom Seo, Kyobin Choo et al.
American Journal of Neuroradiology
Medical Imaging Techniques and Applications
article

The Potency of DCLGAN for Reducing Scan time in PET/CT imaging with different radiotracers of clinical importance

Yeojun Yun, Mijin Yun, Seungbeom Seo, Kyobin Choo, Daesung Kim, Hyunkeong Lim, Ga Yeon Kim, Hyunkyung Han, S M Kang, Sangwon Lee, Dongwoo Kim
article en

Abstract

BACKGROUND AND PURPOSE: Shortening PET/CT acquisition without degrading diagnostic or quantitative performance would improve patient comfort and scanner throughput. We evaluated a Dual-Contrastive Learning GAN (DCLGAN) for reconstructing high-quality neuro-PET images from reduced-time acquisitions across three clinically used tracers (18F-florbetaben (FBB), 18F-FDG, and 18F-FP-CIT) benchmarking against representative state-of-the-art deep learning models. MATERIALS AND METHODS: In this single-center retrospective study of symptomatic patients undergoing neuro-PET/CT, list-mode data from full-time acquisitions (20 min for FBB; 15 min for FDG and FP-CIT) were reconstructed into 3- and 5-minute images. DCLGAN was trained to translate short-time to full-time appearance; raw images and standard 2.5D U-Net served as comparators. Image quality was quantified by normalized root-mean-square error (NRMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). Two blinded nuclear medicine physicians graded clinical image quality on a five-point scale; inter-reader agreement used Cohen's kappa. Quantitative agreement of standardized uptake value ratio (SUVR) for FBB/FDG and specific binding ratio (SBR) for FP-CIT between predicted and full-time images was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. RESULTS: With DCLGAN at 5 minutes, image-quality metrics approached full-time performance across tracers: for FBB, NRMSE 0.018, PSNR 34.721 dB, SSIM 0.963; for FP-CIT, NRMSE 0.008, PSNR 41.889 dB, SSIM 0.982; and for FDG, NRMSE 0.013, PSNR 37.502 dB, SSIM 0.986. Mean reader quality scores for 5-minute DCLGAN images were high-4.48 (FBB), 4.50 (FDG), and 4.55 (FP-CIT)-with strong inter-reader agreement (κ=0.85, 0.83, 0.89, respectively). Quantitative agreement with full-time scans was excellent: ICCs for 5-minute images were 0.997 (FBB), 0.995 (FDG), and 0.996 (FP-CIT). Bland-Altman analyses showed minimal bias (mean bias -0.004 for FBB, 0.012 for FDG, -0.029 for FP-CIT) with narrow limits of agreement. Compared with 3-minute reconstructions, 5-minute DCLGAN images demonstrated significantly higher PSNR/SSIM and lower NRMSE (p<0.001), while maintaining or improving reader scores and quantitative agreement. CONCLUSIONS: Across FBB, FDG, and FP-CIT, DCLGAN enabled 5-minute neuro-PET acquisitions that appeared to maintain reader-rated quality and showed high agreement in SUVR/SBR values with full-time scans. These findings suggest that clinically practical scan-time reduction may be feasible while maintaining interpretability and quantitative integrity in this cohort.

American Journal of Neuroradiology
Yonsei University (KR)
Openalex Percentile: Top 10%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.