The Potency of DCLGAN for Reducing Scan time in PET/CT imaging with different radiotracers of clinical importance
BACKGROUND AND PURPOSE: Shortening PET/CT acquisition without degrading diagnostic or quantitative performance would improve patient comfort and scanner throughput. We evaluated a Dual-Contrastive Learning GAN (DCLGAN) for reconstructing high-quality neuro-PET images from reduced-time acquisitions across three clinically used tracers (18F-florbetaben (FBB), 18F-FDG, and 18F-FP-CIT) benchmarking against representative state-of-the-art deep learning models. MATERIALS AND METHODS: In this single-center retrospective study of symptomatic patients undergoing neuro-PET/CT, list-mode data from full-time acquisitions (20 min for FBB; 15 min for FDG and FP-CIT) were reconstructed into 3- and 5-minute images. DCLGAN was trained to translate short-time to full-time appearance; raw images and standard 2.5D U-Net served as comparators. Image quality was quantified by normalized root-mean-square error (NRMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM). Two blinded nuclear medicine physicians graded clinical image quality on a five-point scale; inter-reader agreement used Cohen's kappa. Quantitative agreement of standardized uptake value ratio (SUVR) for FBB/FDG and specific binding ratio (SBR) for FP-CIT between predicted and full-time images was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. RESULTS: With DCLGAN at 5 minutes, image-quality metrics approached full-time performance across tracers: for FBB, NRMSE 0.018, PSNR 34.721 dB, SSIM 0.963; for FP-CIT, NRMSE 0.008, PSNR 41.889 dB, SSIM 0.982; and for FDG, NRMSE 0.013, PSNR 37.502 dB, SSIM 0.986. Mean reader quality scores for 5-minute DCLGAN images were high-4.48 (FBB), 4.50 (FDG), and 4.55 (FP-CIT)-with strong inter-reader agreement (κ=0.85, 0.83, 0.89, respectively). Quantitative agreement with full-time scans was excellent: ICCs for 5-minute images were 0.997 (FBB), 0.995 (FDG), and 0.996 (FP-CIT). Bland-Altman analyses showed minimal bias (mean bias -0.004 for FBB, 0.012 for FDG, -0.029 for FP-CIT) with narrow limits of agreement. Compared with 3-minute reconstructions, 5-minute DCLGAN images demonstrated significantly higher PSNR/SSIM and lower NRMSE (p<0.001), while maintaining or improving reader scores and quantitative agreement. CONCLUSIONS: Across FBB, FDG, and FP-CIT, DCLGAN enabled 5-minute neuro-PET acquisitions that appeared to maintain reader-rated quality and showed high agreement in SUVR/SBR values with full-time scans. These findings suggest that clinically practical scan-time reduction may be feasible while maintaining interpretability and quantitative integrity in this cohort.
Authors
- Yeojun Yun (ORCID: https://orcid.org/0009-0007-4319-588X)
- Mijin Yun (ORCID: https://orcid.org/0000-0002-1712-163X)
- Seungbeom Seo (ORCID: https://orcid.org/0000-0002-0970-5803)
- Kyobin Choo (ORCID: https://orcid.org/0000-0003-2856-402X)
- Daesung Kim (ORCID: https://orcid.org/0000-0001-6424-6796)
- Hyunkeong Lim
- Ga Yeon Kim
- Hyunkyung Han (ORCID: https://orcid.org/0009-0006-2672-384X)
- S M Kang (ORCID: https://orcid.org/0000-0002-7093-2095)
- Sangwon Lee
- Dongwoo Kim
Institutions
- Yonsei University (KR)
Publication Details
- Journal
- American Journal of Neuroradiology
- Published
- 2026-04-20
- DOI
- https://doi.org/10.3174/ajnr.a9360
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00