Reliability-based optimal design of a hybrid base isolator with an MR-TMDI using multi-condition experimentally identified MR damper parameters under non-stationary ground motion

Conventional passive base isolators often experience large displacement demand that require more advanced architecture to ensure safety and serviceability. To reduce this displacement demand, hybrid base isolation system is often prescribed where the passive isolation system is augmented with additional devices, e.g., a tuned mass damper inerter (TMDI) system along with a magneto-rheological (MR) damper in the present study. An inerter is a two-terminal flywheel where the generated force is proportional to the relative acceleration between its two ends, while a MR damper offers current or magnetic-flux dependent adjustable dynamic properties in real-time. However, their optimal tuning in presence of uncertainty offers serious challenges. With this in view, present study focuses on the reliability-based optimal tuning of hybrid base isolation system where uncertainty associated with MR damper and ground excitation play the vital role. Thus, the damper is tested in the laboratory to experimentally model the random variables. A sparse polynomial chaos expansion based meta model is used to replace the original limit state function for improved computational efficiency. Finally, the response of a full-scale base isolated building is used to compare the algorithm for optimal reliability based tuning of the hybrid system. The results show the enhanced performance of the proposed system compared to the traditional base isolation to simultaneously mitigate the structural response and the isolator displacement demand.

Authors

Institutions

Publication Details

Journal
Journal of Vibration and Control
Published
2026-04-20
DOI
https://doi.org/10.1177/10775463261444766
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability-based optimal design of a hybrid base isolator with an MR-TMDI using multi-condition experimentally identified MR damper parameters under non-stationary ground motion

Arunasis Chakraborty, Swarup Mahato
Journal of Vibration and Control
Vibration Control and Rheological Fluids
article

Reliability-based optimal design of a hybrid base isolator with an MR-TMDI using multi-condition experimentally identified MR damper parameters under non-stationary ground motion

Arunasis Chakraborty, Swarup Mahato
article en

Abstract

Conventional passive base isolators often experience large displacement demand that require more advanced architecture to ensure safety and serviceability. To reduce this displacement demand, hybrid base isolation system is often prescribed where the passive isolation system is augmented with additional devices, e.g., a tuned mass damper inerter (TMDI) system along with a magneto-rheological (MR) damper in the present study. An inerter is a two-terminal flywheel where the generated force is proportional to the relative acceleration between its two ends, while a MR damper offers current or magnetic-flux dependent adjustable dynamic properties in real-time. However, their optimal tuning in presence of uncertainty offers serious challenges. With this in view, present study focuses on the reliability-based optimal tuning of hybrid base isolation system where uncertainty associated with MR damper and ground excitation play the vital role. Thus, the damper is tested in the laboratory to experimentally model the random variables. A sparse polynomial chaos expansion based meta model is used to replace the original limit state function for improved computational efficiency. Finally, the response of a full-scale base isolated building is used to compare the algorithm for optimal reliability based tuning of the hybrid system. The results show the enhanced performance of the proposed system compared to the traditional base isolation to simultaneously mitigate the structural response and the isolator displacement demand.

Journal of Vibration and Control
Indian Institute of Technology Guwahati (IN), Institute of Engineering Science (RU), Indian Institute of Technology Hyderabad (IN)
Affordable and clean energy
Openalex Percentile: Top 13%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reliability-based optimal design of a hybrid base isolator with an MR-TMDI using multi-condition experimentally identified MR damper parameters under non-stationary ground motion — Arunasis Chakraborty, Swarup Mahato · Journal of Vibration and Control (2026) | TGRS Research Map | TGRS