Thermal-fluid-structure coupling simulation of filling process of storage tanks with ultra-low temperature and high-flow-rate

To investigate the tank deformation behavior under ultra-low temperature and high-flow-rate filling conditions, a thermal-fluid-structure coupling numerical model for liquid hydrogen (LH2) filling into the storage tank was established. The temperature variation and corresponding structural deformation of the tank during the ultra-low temperature high-flow-rate LH2 filling process were systematically analyzed. The research findings reveal that at a filling flow rate of 8 m3/min and a pressure difference of 0 MPa, 84.1% of the tank volume was filled with fuel within 960 s, resulting in a deformation of 30.418 mm. When the outlet pressure difference increased from 0 to 0.1 MPa, the fuel filling ratio reached 78.5% in 500 s, with a corresponding deformation of 28.907 mm. As the outlet pressure difference further increased from 0.1 to 0.2 MPa, the filling ratio decreased to 45% with a filling duration of 576 s, and the deformation was reduced to 24.527 mm. When the filling flow rate was increased to 15 m3/min, 44% of the tank volume was filled in 250 s, with a deformation of 27.043 mm. Comparative analysis demonstrates that high-flow-rate LH2 filling achieves significantly higher efficiency than low-flow-rate filling, while the structural deformation induced by high-flow-rate filling is larger than that by low-flow-rate filling. When pre-cooling measures were adopted, the tank deformation after switching to high-flow-rate filling was notably smaller than that without pre-cooling. It is therefore concluded that pre-cooling measures are essential for ultra-low temperature high-flow-rate LH2 filling, as they can significantly improve the LH₂ filling efficiency while effectively reducing the thermal deformation of the tank structure.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-20
DOI
https://doi.org/10.1038/s41598-026-49937-7
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal-fluid-structure coupling simulation of filling process of storage tanks with ultra-low temperature and high-flow-rate

T Chen, Z D Zhang, Jingyuan Chen
Scientific Reports
Spacecraft and Cryogenic Technologies
article

Thermal-fluid-structure coupling simulation of filling process of storage tanks with ultra-low temperature and high-flow-rate

T Chen, Z D Zhang, Jingyuan Chen
article en

Abstract

To investigate the tank deformation behavior under ultra-low temperature and high-flow-rate filling conditions, a thermal-fluid-structure coupling numerical model for liquid hydrogen (LH2) filling into the storage tank was established. The temperature variation and corresponding structural deformation of the tank during the ultra-low temperature high-flow-rate LH2 filling process were systematically analyzed. The research findings reveal that at a filling flow rate of 8 m3/min and a pressure difference of 0 MPa, 84.1% of the tank volume was filled with fuel within 960 s, resulting in a deformation of 30.418 mm. When the outlet pressure difference increased from 0 to 0.1 MPa, the fuel filling ratio reached 78.5% in 500 s, with a corresponding deformation of 28.907 mm. As the outlet pressure difference further increased from 0.1 to 0.2 MPa, the filling ratio decreased to 45% with a filling duration of 576 s, and the deformation was reduced to 24.527 mm. When the filling flow rate was increased to 15 m3/min, 44% of the tank volume was filled in 250 s, with a deformation of 27.043 mm. Comparative analysis demonstrates that high-flow-rate LH2 filling achieves significantly higher efficiency than low-flow-rate filling, while the structural deformation induced by high-flow-rate filling is larger than that by low-flow-rate filling. When pre-cooling measures were adopted, the tank deformation after switching to high-flow-rate filling was notably smaller than that without pre-cooling. It is therefore concluded that pre-cooling measures are essential for ultra-low temperature high-flow-rate LH2 filling, as they can significantly improve the LH₂ filling efficiency while effectively reducing the thermal deformation of the tank structure.

Scientific Reports
Dalian University of Technology (CN), Dalian University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 2%
Spacecraft and Cryogenic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.