Diagnostic validation of a novel high-sensitivity cardiac troponin T assay

AIMS: High-sensitivity cardiac troponin (hs-cTn) assays are integral to evaluating suspected myocardial infarction (MI). A recently developed hs-cTnT assay requires diagnostic and prognostic evaluation. METHODS AND RESULTS: Patients presenting to the emergency department with suspected non-ST-elevation MI were prospectively evaluated. Discrimination was tested using the area under the curve (AUC). Diagnostic performance was assessed with previously derived cut-off concentrations and ESC 0/1 h algorithm. Head-to-head comparisons between the new and established assays were performed. Prognostic performance of hs-cTnT for 1-year mortality and major adverse cardiac events (MACE) was analysed using adjusted Cox regression. In 1415 patients, mean age 64 years and 64.2% male, MI was diagnosed in 12.1%. The novel TnT hs Gen 6 assay demonstrated excellent discrimination with an AUC on admission of 0.87 (95% CI: 0.84, 0.90) and 0.91 (95% CI: 0.89, 0.93) after 1 h. Using a 0 h cut-off <8 ng/L or <18 ng/L and Δ 0/1 h of <2 ng/L enabled rule-out in 54.3% (95% CI: 51.7%, 57.0%), with a NPV of 99.5% (95% CI: 98.7%, 99.9%); sensitivity was 97.7% (95% CI: 94.1%, 99.4%). For rule-in, a 0 h cut-off ≥112 ng/L or a Δ 0/1 h ≥ 10 ng/L yielded a PPV of 58.5% (95% CI: 51.9%, 64.9%) and specificity of 92.2% (95% CI: 90.6%, 93.6%) with rule-in of 16.5% (95% CI: 14.6%, 18.6%). Hs-cTnT was associated with 1-year mortality [hazard ratio (HR) 1.39 (95% CI: 1.28, 1.51)] and MACE [HR 1.22 (95% CI: 1.15, 1.29)]. CONCLUSION: The novel hs-cTnT assay demonstrates high diagnostic accuracy to rule-out or diagnose MI and offers valuable prognostic information regarding 1-year mortality and MACE.Trial Registration: clinicaltrials.gov (NCT02355457).

Authors

Institutions

Publication Details

Journal
European Heart Journal Acute Cardiovascular Care
Published
2026-04-15
DOI
https://doi.org/10.1093/ehjacc/zuag044
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic validation of a novel high-sensitivity cardiac troponin T assay

Betül Toprak, Astrid Petersmann, Raphael Twerenbold, Lea Scharlemann et al.
European Heart Journal Acute Cardiovascular Care
Acute Myocardial Infarction Research
article

Diagnostic validation of a novel high-sensitivity cardiac troponin T assay

Betül Toprak, Astrid Petersmann, Raphael Twerenbold, Lea Scharlemann, Bianca Strauß, Nils A. Sörensen, Niklas Thießen, Karen Friederike Gauß, Jonas Lehmacher, Alina Schock, Beya Abdennadher, Farnaz Dehkordi, Ben Völschow, P M Haller, Johannes T Neumann
article en

Abstract

AIMS: High-sensitivity cardiac troponin (hs-cTn) assays are integral to evaluating suspected myocardial infarction (MI). A recently developed hs-cTnT assay requires diagnostic and prognostic evaluation. METHODS AND RESULTS: Patients presenting to the emergency department with suspected non-ST-elevation MI were prospectively evaluated. Discrimination was tested using the area under the curve (AUC). Diagnostic performance was assessed with previously derived cut-off concentrations and ESC 0/1 h algorithm. Head-to-head comparisons between the new and established assays were performed. Prognostic performance of hs-cTnT for 1-year mortality and major adverse cardiac events (MACE) was analysed using adjusted Cox regression. In 1415 patients, mean age 64 years and 64.2% male, MI was diagnosed in 12.1%. The novel TnT hs Gen 6 assay demonstrated excellent discrimination with an AUC on admission of 0.87 (95% CI: 0.84, 0.90) and 0.91 (95% CI: 0.89, 0.93) after 1 h. Using a 0 h cut-off <8 ng/L or <18 ng/L and Δ 0/1 h of <2 ng/L enabled rule-out in 54.3% (95% CI: 51.7%, 57.0%), with a NPV of 99.5% (95% CI: 98.7%, 99.9%); sensitivity was 97.7% (95% CI: 94.1%, 99.4%). For rule-in, a 0 h cut-off ≥112 ng/L or a Δ 0/1 h ≥ 10 ng/L yielded a PPV of 58.5% (95% CI: 51.9%, 64.9%) and specificity of 92.2% (95% CI: 90.6%, 93.6%) with rule-in of 16.5% (95% CI: 14.6%, 18.6%). Hs-cTnT was associated with 1-year mortality [hazard ratio (HR) 1.39 (95% CI: 1.28, 1.51)] and MACE [HR 1.22 (95% CI: 1.15, 1.29)]. CONCLUSION: The novel hs-cTnT assay demonstrates high diagnostic accuracy to rule-out or diagnose MI and offers valuable prognostic information regarding 1-year mortality and MACE.Trial Registration: clinicaltrials.gov (NCT02355457).

European Heart Journal Acute Cardiovascular Care
Carl von Ossietzky Universität Oldenburg (DE), Universität Hamburg (DE), Universitätsmedizin Greifswald (DE), General Department of Preventive Medicine (VN), University Medical Center Hamburg-Eppendorf (DE), German Centre for Cardiovascular Research (DE), Medical University of Vienna (AT)
Abbott Laboratories, Amgen, Roche, Joachim Herz Stiftung, Deutsches Zentrum für Herz-Kreislaufforschung, Providence Health Care, Singulex, Roche España, Deutsche Forschungsgemeinschaft, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Schweizerische Herzstiftung, Siemens, Siemens Healthineers, Roche Diagnostics
Peace, Justice and strong institutions
Openalex Percentile: Top 15%
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.