Predictive value of ventriculo-arterial coupling for hypotension after induction of anaesthesia: a prospective observational cohort study

BACKGROUND: Post-induction hypotension (PIH) is associated with acute perioperative organ injury. We quantified the added value of echocardiographic parameters and ventriculo-arterial coupling (VAC)-related variables for the prediction of PIH. METHODS: ) was derived pre-operatively using transthoracic echocardiography combined with non-invasive blood pressure measurements. PIH was defined as the first occurrence of mean arterial pressure < 65 mmHg between anaesthesia induction and surgical incision. Predictors were analysed using a generalised additive model to account for potential non-linear associations. Incremental prognostic value was assessed using the fraction of new information (FNI), a reclassification-based metric, and changes in the area under the receiver operating characteristic curve (AUC). RESULTS: ratio > 1 was associated with PIH (OR 2.95; 95% CI 1.08-8.03; p = 0.034). The clinical model showed an AUC of 0.720 (95% CI 0.669-0.771). The addition of echocardiographic parameters increased the AUC to 0.768 (95% CI 0.720-0.816; Holm-adjusted p = 0.018) and provided 37% FNI (Holm-adjusted p = 0.199). The incorporation of VAC-related variables further increased the AUC to 0.785 (95% CI 0.739-0.831; Holm-adjusted p = 0.002) and yielded 46% FNI (Holm-adjusted p = 0.030). Compared with the clinical-echocardiographic model, incorporation of VAC-related variables provided an additional 14% FNI (Holm-adjusted p = 0.018) without a statistically significant AUC increase (0.017; 95% CI -0.004-0.039; Holm-adjusted p = 0.199). CONCLUSION: ratio > 1. Incorporation of echocardiographic parameters improved the discriminatory performance of a clinical prediction model, and the further addition of VAC-related variables provided meaningful improvement in risk reclassification, despite only modest gains in overall discrimination.

Authors

Institutions

Publication Details

Journal
Intensive Care Medicine Experimental
Published
2026-04-21
DOI
https://doi.org/10.1186/s40635-026-00899-0
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictive value of ventriculo-arterial coupling for hypotension after induction of anaesthesia: a prospective observational cohort study

Yvon Deryck, Tôn Ngọc Vũ Phan, Trung Hiếu Dương, Thi Thu Trang Nguyen et al.
Intensive Care Medicine Experimental
Hemodynamic Monitoring and Therapy
article

Predictive value of ventriculo-arterial coupling for hypotension after induction of anaesthesia: a prospective observational cohort study

Yvon Deryck, Tôn Ngọc Vũ Phan, Trung Hiếu Dương, Thi Thu Trang Nguyen, Hồng Chính Lê, Huu Khanh Trinh Dong, Tran Huy Nhat Phung, Minh Khoi Le, Chau Bich Ha Tran, Duc Nam Nguyen
article en

Abstract

BACKGROUND: Post-induction hypotension (PIH) is associated with acute perioperative organ injury. We quantified the added value of echocardiographic parameters and ventriculo-arterial coupling (VAC)-related variables for the prediction of PIH. METHODS: ) was derived pre-operatively using transthoracic echocardiography combined with non-invasive blood pressure measurements. PIH was defined as the first occurrence of mean arterial pressure < 65 mmHg between anaesthesia induction and surgical incision. Predictors were analysed using a generalised additive model to account for potential non-linear associations. Incremental prognostic value was assessed using the fraction of new information (FNI), a reclassification-based metric, and changes in the area under the receiver operating characteristic curve (AUC). RESULTS: ratio > 1 was associated with PIH (OR 2.95; 95% CI 1.08-8.03; p = 0.034). The clinical model showed an AUC of 0.720 (95% CI 0.669-0.771). The addition of echocardiographic parameters increased the AUC to 0.768 (95% CI 0.720-0.816; Holm-adjusted p = 0.018) and provided 37% FNI (Holm-adjusted p = 0.199). The incorporation of VAC-related variables further increased the AUC to 0.785 (95% CI 0.739-0.831; Holm-adjusted p = 0.002) and yielded 46% FNI (Holm-adjusted p = 0.030). Compared with the clinical-echocardiographic model, incorporation of VAC-related variables provided an additional 14% FNI (Holm-adjusted p = 0.018) without a statistically significant AUC increase (0.017; 95% CI -0.004-0.039; Holm-adjusted p = 0.199). CONCLUSION: ratio > 1. Incorporation of echocardiographic parameters improved the discriminatory performance of a clinical prediction model, and the further addition of VAC-related variables provided meaningful improvement in risk reclassification, despite only modest gains in overall discrimination.

Intensive Care Medicine ExperimentalVol. 14(1)
Université de Bordeaux (FR), Inserm (FR), Ghent University Hospital (BE), University of Medicine and Pharmacy at Ho Chi Minh City (VN), University Medical Center HCMC (VN), Bordeaux Population Health (FR)
Openalex Percentile: Top 21%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.