Impact of artificial intelligence-based automated segmentation on the accuracy of robotic computer-aided implant surgery: a retrospective study.

Objectives This retrospective study aimed to evaluate the impact of artificial intelligence (AI)-based automated segmentation (AS) on the accuracy of robotic computer-aided implant surgery (r-CAIS).Methods Patients who underwent r-CAIS were enrolled. Preoperative CBCT images were segmented using either threshold-based SS approach (SS group) or the AI-based AS approach (AS group). Osteotomy preparation and implant placement were performed using a semi-active robot. Registration errors and deviations between planned and postoperatively placed implant positions were calculated. Intergroup comparisons were performed using Wilcoxon Mann-Whitney U tests, with P < 0.05 considered significant.Results A total of 140 patients (79 females, 61 males) receiving 224 implants were included (SS group: 69 patients, 107 implants; AS group: 71 patients, 117 implants). The registration error in the AS group (0.10 ± 0.04 mm) was significantly lower than that in the SS group (0.12 ± 0.04 mm) (P < 0.05). The AS group demonstrated lower deviations at the platform (0.51 ± 0.16 vs.0.56 ± 0.18 mm), apex (0.60 ± 0.23 vs. 0.66 ± 0.23 mm), and angulation (1.13 ± 0.59° vs. 1.19 ± 0.53°), with a statistically significant difference observed in global platform deviation (P < 0.05).Conclusions r-CAIS demonstrated consistently high accuracy, which was further improved by AI-based AS. This improvement may be associated with enhanced registration precision achieved through AI-based AS.Clinical Significance These findings support the potential clinical application of AI-based AS in r-CAIS.

Authors

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-04-13
DOI
https://doi.org/10.48620/97050
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of artificial intelligence-based automated segmentation on the accuracy of robotic computer-aided implant surgery: a retrospective study.

Wen Long, Zhaoli Meng, Lifan Liao, Qin Zhou et al.
Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Impact of artificial intelligence-based automated segmentation on the accuracy of robotic computer-aided implant surgery: a retrospective study.

Wen Long, Zhaoli Meng, Lifan Liao, Qin Zhou, Longlong He, Rongrong Zhu, Ningbo Zhao, Jianfei Liang
article en

Abstract

Objectives This retrospective study aimed to evaluate the impact of artificial intelligence (AI)-based automated segmentation (AS) on the accuracy of robotic computer-aided implant surgery (r-CAIS).Methods Patients who underwent r-CAIS were enrolled. Preoperative CBCT images were segmented using either threshold-based SS approach (SS group) or the AI-based AS approach (AS group). Osteotomy preparation and implant placement were performed using a semi-active robot. Registration errors and deviations between planned and postoperatively placed implant positions were calculated. Intergroup comparisons were performed using Wilcoxon Mann-Whitney U tests, with P < 0.05 considered significant.Results A total of 140 patients (79 females, 61 males) receiving 224 implants were included (SS group: 69 patients, 107 implants; AS group: 71 patients, 117 implants). The registration error in the AS group (0.10 ± 0.04 mm) was significantly lower than that in the SS group (0.12 ± 0.04 mm) (P < 0.05). The AS group demonstrated lower deviations at the platform (0.51 ± 0.16 vs.0.56 ± 0.18 mm), apex (0.60 ± 0.23 vs. 0.66 ± 0.23 mm), and angulation (1.13 ± 0.59° vs. 1.19 ± 0.53°), with a statistically significant difference observed in global platform deviation (P < 0.05).Conclusions r-CAIS demonstrated consistently high accuracy, which was further improved by AI-based AS. This improvement may be associated with enhanced registration precision achieved through AI-based AS.Clinical Significance These findings support the potential clinical application of AI-based AS in r-CAIS.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 5%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.