Removal of Antimony by Volatilization from Photovoltaic Glass with Sucrose under Anoxic Environment

In the recycling of photovoltaic (PV) modules, promoting the recycling of PV glasswhich accounts for approximately 60% of the total module weightis crucial. However, PV glass contains antimony (Sb) to enhance its transmittance, and this antimony poses a barrier to recycling in float baths. In this study, we investigated the feasibility of removing Sb from PV glass by volatilization using chloride and reductive methods. We also estimated the reactions using thermodynamic equilibrium calculations and evaluated the volatilization mechanism of Sb from PV glass. The results showed that, unlike conventional chloride volatilization and chloride reduction methods, operation under a non-oxygen atmosphere and the use of sucrose as a reducing agent are important for Sb removal by volatilization. The degree of influence of each experimental condition on Sb volatilization was highest for the gas atmosphere (N2) and sucrose, followed by heating temperature and C/Sb molar ratio. Under experimental conditions used in this study, heating time is considered to have a low degree of influence. The optimal conditions for Sb volatilization in the experiments were a heating temperature of 1100 °C, a heating time of 120 min, and a C/Sb molar ratio of 224, which yield a Sb volatilization rate of 92.6%. By contrast, thermodynamic equilibrium calculations showed that at a heating temperature of 500 °C, the Sb volatilization rate was 100%, and at a C/Sb molar ratio of 11.2, the rate was 92.8%. These results suggest that the heating temperature and C/Sb molar ratio can be reduced by increasing the reactivity of the sample. PV glass after heating is considered recyclable as raw material for flat glass and can be used as antimony-free or low-antimony glass material. Therefore, the Sb volatilization removal method developed in this study is expected to significantly reduce barriers to recycling.

Authors

Institutions

Publication Details

Journal
ACS Sustainable Resource Management
Published
2026-04-17
DOI
https://doi.org/10.1021/acssusresmgt.6c00175
Primary Topic
Photovoltaic Systems and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Removal of Antimony by Volatilization from Photovoltaic Glass with Sucrose under Anoxic Environment

Shinji Mizuhara, Takashi Fujimori, Naoya Wada, Hitomi Akutsu et al.
ACS Sustainable Resource Management
Photovoltaic Systems and Sustainability
article

Removal of Antimony by Volatilization from Photovoltaic Glass with Sucrose under Anoxic Environment

Shinji Mizuhara, Takashi Fujimori, Naoya Wada, Hitomi Akutsu, Tomonori Takemoto, Hanamichi Iwamuro, Satoshi Kita
article en

Abstract

In the recycling of photovoltaic (PV) modules, promoting the recycling of PV glasswhich accounts for approximately 60% of the total module weightis crucial. However, PV glass contains antimony (Sb) to enhance its transmittance, and this antimony poses a barrier to recycling in float baths. In this study, we investigated the feasibility of removing Sb from PV glass by volatilization using chloride and reductive methods. We also estimated the reactions using thermodynamic equilibrium calculations and evaluated the volatilization mechanism of Sb from PV glass. The results showed that, unlike conventional chloride volatilization and chloride reduction methods, operation under a non-oxygen atmosphere and the use of sucrose as a reducing agent are important for Sb removal by volatilization. The degree of influence of each experimental condition on Sb volatilization was highest for the gas atmosphere (N2) and sucrose, followed by heating temperature and C/Sb molar ratio. Under experimental conditions used in this study, heating time is considered to have a low degree of influence. The optimal conditions for Sb volatilization in the experiments were a heating temperature of 1100 °C, a heating time of 120 min, and a C/Sb molar ratio of 224, which yield a Sb volatilization rate of 92.6%. By contrast, thermodynamic equilibrium calculations showed that at a heating temperature of 500 °C, the Sb volatilization rate was 100%, and at a C/Sb molar ratio of 11.2, the rate was 92.8%. These results suggest that the heating temperature and C/Sb molar ratio can be reduced by increasing the reactivity of the sample. PV glass after heating is considered recyclable as raw material for flat glass and can be used as antimony-free or low-antimony glass material. Therefore, the Sb volatilization removal method developed in this study is expected to significantly reduce barriers to recycling.

ACS Sustainable Resource Management
Ryukoku University (JP), Fukushima Technology Centre (Japan) (JP), GC Corporation (Japan) (JP)
Openalex Percentile: Top 11%
Photovoltaic Systems and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.