Mechanobiological design strategy for additively manufacturable tibial ankle implant for enhanced biomechanical and osseointegration performance: A finite element and machine learning approach

The leading cause of revision surgeries in ankle arthroplasty is aseptic loosening of the tibial implant, resulting from adverse bone remodelling and insufficient osseointegration. Aseptic loosening depends on multiple factors, such as the design of the implant, the porous surface of the implant, the quality of bone, implant positioning, wear debris, etc. The extent to which the design of porous architecture and its relationship with aseptic loosening failure mechanisms remains unexplored. The study aims to identify the lattice design of porous rhombic dodecahedron architecture of tibial implants that would be able to maximise bone formation and reduce stress shielding using macro-micro finite element (FE) analysis with machine learning (ML) approach. The study entails the macro-microscale FE modelling of four porous rhombic dodecahedron tibial implants (PRDTI), referred as PRDTI50, PRDTI60, PRDTI70, and PRDTI80. Based on macro-micro-FE determined dataset, four artificial neural network (ANN)-based ML algorithms were trained and validated for faster prediction of bone ingrowth. Results evidenced that von Mises stress in the tibia exhibited elevated stresses for PRDTI80 and PRDTI70 implants compared to PRDTI60, PRDTI50, and solid implant. Bone ingrowth results indicated that the PRDTI70 implant exhibited higher amounts of bone formation. The study proposes the PRDTI70 implant is a viable option for designing tibial implants to simultaneously reduce stress shielding and maximises bone ingrowth. This preclinical analysis sheds light on the role of porous structure design in bone formation for the development of porous tibial prostheses for TAR to prevent revision instances.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2026-04-16
DOI
https://doi.org/10.1177/09544119261439570
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanobiological design strategy for additively manufacturable tibial ankle implant for enhanced biomechanical and osseointegration performance: A finite element and machine learning approach

Rajesh Ghosh, Minku
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Total Knee Arthroplasty Outcomes
article

Mechanobiological design strategy for additively manufacturable tibial ankle implant for enhanced biomechanical and osseointegration performance: A finite element and machine learning approach

Rajesh Ghosh, Minku
article en

Abstract

The leading cause of revision surgeries in ankle arthroplasty is aseptic loosening of the tibial implant, resulting from adverse bone remodelling and insufficient osseointegration. Aseptic loosening depends on multiple factors, such as the design of the implant, the porous surface of the implant, the quality of bone, implant positioning, wear debris, etc. The extent to which the design of porous architecture and its relationship with aseptic loosening failure mechanisms remains unexplored. The study aims to identify the lattice design of porous rhombic dodecahedron architecture of tibial implants that would be able to maximise bone formation and reduce stress shielding using macro-micro finite element (FE) analysis with machine learning (ML) approach. The study entails the macro-microscale FE modelling of four porous rhombic dodecahedron tibial implants (PRDTI), referred as PRDTI50, PRDTI60, PRDTI70, and PRDTI80. Based on macro-micro-FE determined dataset, four artificial neural network (ANN)-based ML algorithms were trained and validated for faster prediction of bone ingrowth. Results evidenced that von Mises stress in the tibia exhibited elevated stresses for PRDTI80 and PRDTI70 implants compared to PRDTI60, PRDTI50, and solid implant. Bone ingrowth results indicated that the PRDTI70 implant exhibited higher amounts of bone formation. The study proposes the PRDTI70 implant is a viable option for designing tibial implants to simultaneously reduce stress shielding and maximises bone ingrowth. This preclinical analysis sheds light on the role of porous structure design in bone formation for the development of porous tibial prostheses for TAR to prevent revision instances.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Centre National de la Recherche Scientifique (FR), Laboratoire Jean-Alexandre Dieudonné (FR), Indian Institute of Technology Mandi (IN)
Openalex Percentile: Top 9%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.