Assessing Mass Screening as an Effective Tool for Pandemic Management: An Experimental Study of SARS-CoV-2 Diagnosis

SARS-CoV-2 infection has emerged worldwide. To reduce the number of cases and limit the transmission of the virus, health and local authorities have implemented several strategies. Mass screening is a key strategy for mitigating the damage caused by this pandemic. This strategy is based on the use of qRT-PCR and pooling to diagnose SARS-CoV-2 infection. The present work explores the performance and limitations of this strategy for the molecular diagnosis of SARS-CoV-2 infection. Three important technical aspects were retained: the comparison of two commercial extraction kits (BIGFISH and BIOER), the simulation of a non-compliant nasopharyngeal swab, and the evaluation of the pooling strategy. A total of 97 SARS-CoV-2-positive nasopharyngeal samples were used. The comparison of the two extraction kits was based on threshold cycles (Ct) values. The results showed a significant difference (IC = 95%) in the Ct of the nucleocapsid gene (N; p = 0.0000384) and RNA-dependent RNA polymerase (RdRp; p = 0.0254). However, no significant difference was observed between the Internal Control gene (IC; p = 0.0723) and Envelope gene (E; p = 0.150). The Ct values resulting from the BIGFISH extraction kit were generally lower than those obtained from BIOER. In terms of sensitivity, the RT-qPCR technique allows for the detection of viral RNA up to 10−3 as a dilution factor. This study demonstrated that the pooling strategy is an effective diagnostic technique. Positive samples remained detectable even in pools of 1000 or even 10,000 samples. However, the size of the pool under diagnostic conditions should not exceed a limit that must be dynamically adapted to prevalence to ensure economic and analytical viability.

Authors

Institutions

Publication Details

Journal
Pandemics
Published
2026-04-17
DOI
https://doi.org/10.3390/pandemics1010005
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Mass Screening as an Effective Tool for Pandemic Management: An Experimental Study of SARS-CoV-2 Diagnosis

Mohamed Aghrouch, Ahmed Belmouden, Adil Lagmar, Maryem Wardi et al.
Pandemics
SARS-CoV-2 detection and testing
article

Assessing Mass Screening as an Effective Tool for Pandemic Management: An Experimental Study of SARS-CoV-2 Diagnosis

Mohamed Aghrouch, Ahmed Belmouden, Adil Lagmar, Maryem Wardi, Zohra Lemkhente
article en

Abstract

SARS-CoV-2 infection has emerged worldwide. To reduce the number of cases and limit the transmission of the virus, health and local authorities have implemented several strategies. Mass screening is a key strategy for mitigating the damage caused by this pandemic. This strategy is based on the use of qRT-PCR and pooling to diagnose SARS-CoV-2 infection. The present work explores the performance and limitations of this strategy for the molecular diagnosis of SARS-CoV-2 infection. Three important technical aspects were retained: the comparison of two commercial extraction kits (BIGFISH and BIOER), the simulation of a non-compliant nasopharyngeal swab, and the evaluation of the pooling strategy. A total of 97 SARS-CoV-2-positive nasopharyngeal samples were used. The comparison of the two extraction kits was based on threshold cycles (Ct) values. The results showed a significant difference (IC = 95%) in the Ct of the nucleocapsid gene (N; p = 0.0000384) and RNA-dependent RNA polymerase (RdRp; p = 0.0254). However, no significant difference was observed between the Internal Control gene (IC; p = 0.0723) and Envelope gene (E; p = 0.150). The Ct values resulting from the BIGFISH extraction kit were generally lower than those obtained from BIOER. In terms of sensitivity, the RT-qPCR technique allows for the detection of viral RNA up to 10−3 as a dilution factor. This study demonstrated that the pooling strategy is an effective diagnostic technique. Positive samples remained detectable even in pools of 1000 or even 10,000 samples. However, the size of the pool under diagnostic conditions should not exceed a limit that must be dynamically adapted to prevalence to ensure economic and analytical viability.

PandemicsVol. 1(1)
Université Ibn Zohr (MA)
Centre National pour la Recherche Scientifique et Technique
Good health and well-being
Openalex Percentile: Top 14%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.