Evaluation of Quantitative Methods for Energy‐Dispersive X‐Ray Fluorescence Analysis of Silicic Samples in Archeology and Geochemistry

ABSTRACT A series of quantitative methods—the fundamental parameter (FP) and calibration curve methods—were evaluated for reliable routine analysis of archeological and geochemical silicic samples (e.g., pottery, clay, rock, and soil) using energy‐dispersive X‐ray fluorescence (EDXRF) spectrometry to determine their provenance. Calibration curves for 22 components (Na 2 O, MgO, Al 2 O 3 , SiO 2 , P 2 O 5 , K 2 O, CaO, TiO 2 , MnO, Fe 2 O 3 , V, Cr, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb, Ba, and Pb) were constructed from 12 geochemical reference materials (RMs). A total of 15 of the 22 components exhibited poor linearity, with correlation coefficients of 0.774–0.987. The accuracy of the calibration curve, standardless FP, and FP methods calibrated with 12 RMs was evaluated by measuring six additional geochemical RMs. Comparison with the recommended values showed that the FP method calibrated with RMs was the most accurate, whereas the calibration curve and standardless FP methods showed comparable, but lower, accuracy. These results indicate that, for EDXRF analysis of archeological and geochemical silicic samples, the FP method calibrated with RMs is more appropriate and less time‐consuming than constructing calibration curves. Furthermore, the number of RMs used to calibrate the FP method was reduced from 12 to 6, and the reliability was evaluated by measuring the same six additional geochemical RMs. The results showed that the FP method calibrated with 12 and 6 RMs achieved generally equivalent accuracy, indicating that the number of RMs can be reduced without compromising reliability, thereby lowering the calibration effort.

Authors

Institutions

Publication Details

Journal
X-Ray Spectrometry
Published
2026-04-17
DOI
https://doi.org/10.1002/xrs.70106
Primary Topic
Cultural Heritage Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Quantitative Methods for Energy‐Dispersive X‐Ray Fluorescence Analysis of Silicic Samples in Archeology and Geochemistry

Shintaro Ichikawa, Tsutomu Kurisaki, Narumi Kitajima
X-Ray Spectrometry
Cultural Heritage Materials Analysis
article

Evaluation of Quantitative Methods for Energy‐Dispersive X‐Ray Fluorescence Analysis of Silicic Samples in Archeology and Geochemistry

Shintaro Ichikawa, Tsutomu Kurisaki, Narumi Kitajima
article en

Abstract

ABSTRACT A series of quantitative methods—the fundamental parameter (FP) and calibration curve methods—were evaluated for reliable routine analysis of archeological and geochemical silicic samples (e.g., pottery, clay, rock, and soil) using energy‐dispersive X‐ray fluorescence (EDXRF) spectrometry to determine their provenance. Calibration curves for 22 components (Na 2 O, MgO, Al 2 O 3 , SiO 2 , P 2 O 5 , K 2 O, CaO, TiO 2 , MnO, Fe 2 O 3 , V, Cr, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb, Ba, and Pb) were constructed from 12 geochemical reference materials (RMs). A total of 15 of the 22 components exhibited poor linearity, with correlation coefficients of 0.774–0.987. The accuracy of the calibration curve, standardless FP, and FP methods calibrated with 12 RMs was evaluated by measuring six additional geochemical RMs. Comparison with the recommended values showed that the FP method calibrated with RMs was the most accurate, whereas the calibration curve and standardless FP methods showed comparable, but lower, accuracy. These results indicate that, for EDXRF analysis of archeological and geochemical silicic samples, the FP method calibrated with RMs is more appropriate and less time‐consuming than constructing calibration curves. Furthermore, the number of RMs used to calibrate the FP method was reduced from 12 to 6, and the reliability was evaluated by measuring the same six additional geochemical RMs. The results showed that the FP method calibrated with 12 and 6 RMs achieved generally equivalent accuracy, indicating that the number of RMs can be reduced without compromising reliability, thereby lowering the calibration effort.

X-Ray Spectrometry
Fukuoka University (JP)
Fukuoka University, Japan Society for the Promotion of Science
Openalex Percentile: Top 11%
Cultural Heritage Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.